![JUKI HZL-K65 Service Manual Download Page 35](http://html.mh-extra.com/html/juki/hzl-k65/hzl-k65_service-manual_2029831035.webp)
SERVICE MANUAL
Date:
2011/09/23
Page:
35/39
Model:
K65&K85
SEC. 13
Retaining bracket for bobbin case
1.
Remove needle plate.
2.
Loosen screw (a & b) and adjust the position of retaining bracket until the
projection (c) of bobbin case can be positioned against the plate spring.
3.
Place needle plate into position
、
check clearance between projection of bobbin
case when move bobbin case in reverse rotation. Clearance is 1 to 2 mm.
Retainer for reverse rotation
c
Plate spring
a
b