– 72 –
(14) Adjustment of external parts
3) Adjustment of the bobbin winder unit
Let the bobbin winder lever
coincide with the head of bobbin
winder unit setscrew
.
B
14mm
In the state of OFF, the standard
distance of the bobbin winder
lever
is 14mm from the bobbin
winder shaft
.
Standard Adjustment
Operator side
Summary of Contents for DDL-9000A
Page 14: ... 10 4 Feed locus and phase 1 Timing standard 2 Timing fast 3 Timing slow Standard Adjustment ...
Page 32: ... 28 8 Adjustment of the amount of feeding 4 Optional switch Standard Adjustment ...
Page 60: ... 56 11 Thread trimming unit 7 Replacement of the moving knife Standard Adjustment ...
Page 66: ... 62 11 Thread trimming unit 10 Adjustment of the drive arm stopper Standard Adjustment ...
Page 70: ... 66 12 Adjustment of the wiper DDL 9000A WB OB 2mm 1mm Standard Adjustment ...
Page 72: ... 68 13 Adjustment of feed lever pressure B A Feed lever Standard Adjustment ...