– 101 –
4-3) The tension of the needle thread
Reduce the tension of the needle thread. Use silicon.
is too high.
4-4) The speed is too high.
Reduce the speed.
4-5) The feed timing is inappropriate.
5-A) The needle is bent by the thick
Hasten the feed timing.
(needle bent)
portion.
4-6) The thread take-up spring is
6-A) The stroke of the thread take-up
Shorten the stroke of the thread take-up spring.
inappropriately adjusted.
spring is too long.
6-B) The tension of the thread take-up
Reduce the tension of the thread take-up spring.
spring is too high.
4-7) The material is inappropriately
7-A) The presser is floating.
Adjust the clearance between the presser bar holder and
stretched.
lifting plate.
7-B) The needle hole of the throat
Use a throat plate with a smaller needle hole.
plate is too large.
7-C) The thread relief on the back
Use a foot with a smaller thread relief on the backside or
side of the presser is too large.
without thread relief.
7-D) The parallel level of the presser
Replace the presser, or loosen the presser bar holding
is inappropriate.
screw and correct the foot bend.
5. Needle thread breakage
5-1) The thread path (including the
1-A) The thread path is not smooth.
Finish the thread path appropriately.
throat plate and foot) is defective
1-B) The thread path has a flaw.
Finish the thread path appropriately.
1-C) The thread path has an obstacle.
Check threading again and conduct correction if necessary.
5-2) The tension of the needle thread
2-A) The tension of the needle thread
Adjust the tension of the needle thread to the appropriate
is inappropriate.
is too high or too low.
level.
2-B) The 1st thread tension is too low.
Adjust the tension of the needle thread to eliminate random
movement of the thread between the 1st and 2nd thread
tension portions.
5-3) The thread take-up spring is
3-A) The stroke of the thread take-up
Adjust the stroke of the thread take-up spring.
inappropriately adjusted.
spring is too long or too small.
3-B) The tension of the thread take-up
Adjust the tension of the thread take-up spring.
spring is too high or too low.
3-C) Spring selection for the thread
For the A-type thread tension, replace the current thread
to be used is inappropriate.
take-up spring with a standard type spring.
(for a #60 or thicker thread)
Trouble
Case (1)
Case (2)
Check and Corrective measures
To the next page
From the previous page
Summary of Contents for DDL-9000A
Page 14: ... 10 4 Feed locus and phase 1 Timing standard 2 Timing fast 3 Timing slow Standard Adjustment ...
Page 32: ... 28 8 Adjustment of the amount of feeding 4 Optional switch Standard Adjustment ...
Page 60: ... 56 11 Thread trimming unit 7 Replacement of the moving knife Standard Adjustment ...
Page 66: ... 62 11 Thread trimming unit 10 Adjustment of the drive arm stopper Standard Adjustment ...
Page 70: ... 66 12 Adjustment of the wiper DDL 9000A WB OB 2mm 1mm Standard Adjustment ...
Page 72: ... 68 13 Adjustment of feed lever pressure B A Feed lever Standard Adjustment ...
Page 112: ...MEMO ...