![JUKI DDL-8100B-7 Series Instruction Manual Download Page 50](http://html1.mh-extra.com/html/juki/ddl-8100b-7-series/ddl-8100b-7-series_instruction-manual_2029672050.webp)
– 48 –
No.
Description of error
detected
Cause of occurrence expected
Items to be checked
E813 Low voltage
• When voltage lower than guaranteed
one is inputted.
• 120V is applied to 220V box.
• Check whether the voltage is lower than the
rated voltage - (minus) 10% or less.
• Inner circuit is broken by the applied
overvoltage.
• Check whether fuse or regenerative resis
-
tance is broken.
E922 Main shaft uncontrol-
lable
• In the case the main shaft cannot be
controlled.
E924 Motor driver failure
• Motor driver has broken.
E930 Faulty encoder
• In the case a motor signal cannot be
input correctly.
• Check the motor signal connector (CN30)
for looseness and slip-off.
• Check whether the motor signal cord is
caught in the machine head or has a break.
E931 Motor hole sensor
failure
E942 Faulty EEPROM
• Data cannot be written on the EEPROM.