– 76 –
4. Pull out the panel
❺
short.
5. Remove the panel cable clamp screw
❻
, remove
the cable connector
❼
, and replace the panel
❺
.
6. After replacement of the panel, reassemble it ac-
cording to the opposite procedure.
(Caution) Pull the panel cable
❸
.If it is loose, it
may interfere with the upper shaft and
the like.
Secure the laid cable with a cable clip band.
If a cable clip band is not available right now, refer to
"When a cable clip band is not available right now" on
the next page for a provisional means.
❺
❻
❼
❸
Completion