![JUKI AW-3S Instruction Manual Download Page 47](http://html1.mh-extra.com/html/juki/aw-3s/aw-3s_instruction-manual_2029432047.webp)
– 45 –
Display and
description of
error
Cause
Error handling procedure
E076
Bobbin-thread
winding is not
carried out nor-
mally.
①
Obstacles such as dust, etc.
gather on the moving section.
○ Carry out maintenance referring to
.
②
Thread of the bobbin thread
cone has run out during wind-
ing of a bobbin.
○ Put the bobbin thread cone in place.
③
Thread has broken during
winding of a bobbin.
○ Referring to
"3-2. How to thread the device with
, check the thread ten-
sion.
④
Thread wound on the bobbin
overflows from the bobbin
flange.
○ Check the setting of bobbin-thread winding length.
○
Check whether or not the thread used in the previous
sewing still remains on the bobbin.
⑤
Bobbin fails to rotate.
○ Referring to
"3-3. How to set a bobbin" p.8
,
check whether or not the bobbin is fitted in the bob
-
bin case correctly.
⑥
Thread slips out of the roller of
bobbin thread feeding unit.
○ If the thread tension is not sufficient, thread may
slip off the roller. Check the thread tension.
⑦
Bobbin thread feeding unit fails
to operate.
○ Check whether or not the connector, air tube, etc.
coming from the bobbin thread feeding unit are
correctly connected.
⑧
Thread has tangled on the
thread stand, etc. since the
thread has vibrated excessive-
ly halfway through threading
route.
○ Check the threading route referring to
to thread the device with the bobbin thread"
. In particular, the roller and actuating arm,
etc. of the bobbin thread feeding unit are threaded
correctly.
E311
Cover of the
AW device is
left opened.
①
Cover is left opened.
○ Check the cover status.
②
Microswitch is not correctly
positioned.
○ Check the position of the microswitch.
③
Microswitch cable is discon-
nected.
○ Check whether the microswitch cable is connected
to the AMS main PCB.
④
There is no microswitch signal.
○ Check the microswitch signal.