![JUKI AW-3S Instruction Manual Download Page 19](http://html1.mh-extra.com/html/juki/aw-3s/aw-3s_instruction-manual_2029432019.webp)
– 17 –
A
3-10. Operating the AW
When
A
is pressed on the data input screen, the AW opera-
tion screen is displayed.
At this time, the bobbin check screen is displayed when no bobbin
is loaded in the device, or the error screen is displayed when an
AW error has occurred. On these screens, the error will be reset by
completing loading of a bobbin.
The AW operation screen is displayed after resetting the error.
Ⓐ
Ⓑ
Ⓒ
Ⓔ
Ⓓ
B
When one of the following buttons is pressed on the AW operation
screen, the corresponding independent operation of AW can be
carried out.
Press
B
to close the screen.
Ⓐ
: Bobbin change button
Ⓑ
: Bobbin take-out button
Ⓒ
: Empty bobbin loading button
Ⓓ
: Threaded bobbin loading button
Ⓔ
: Nozzle air button
Detailed explanation will be given from the next page.
<Data input screen>
<AW operation screen>
Be aware that an error can be caused if the bobbin in
hook
❶
is directly changed, etc. by hand without oper
-
ating the AW operation screen after turning the power
ON.