– 5 –
1. Fix the throat plate auxiliary
cover
❸
so that is higher than
the throat plate
❷
(within 0.3
mm). When it is lower than
the throat plate
❷
, needle
breakage or the like due to the
defective feed will be caused.
2. Confirm by putting a ruler or
the like that the throat plate
auxiliary cover
❸
is horizon-
tally installed. If not, throat
plate auxiliary cover
❸
and
lower plate
❶
come in contact
partially with each other, and
abnormal worn-out will be
caused.
3-4. Installing the panel
1) Open cover
❶
and remove cable
❷
once.
Then connect it again to the panel on the top
surface of the table after passing it through the
hole in the table.
2) Fix operation panel installing plate
❸
to an op-
tional place on the table with two wood screws
❹
.
Install the panel at the position where
X-move cover or head grip does not
interfere with it since breakage of the
panel will be caused.
Installing the IP-420
❷
❶
❸
❹
Within 0.3 mm
❸
❸
❷
❸
❶