No.
Item
Setting range
28
0 to 100ms
10ms
20
29
0 to 10000ms
100ms
0
(0: No timeout)
Ineffective
30
—
Effective
Standard
31
—
Extension unit
32
100 to 3000pps
10pps
3000
33
100 to 3000pps
10pps
3000
Without
34
—
With
Without
35
—
With
36
0 to 100.0mm
0.1mm
17.0
37
100 to 10000ms
10ms
400
38
100 to 10000ms
10ms
1200
39
100 to 2000pps
10pps
1000
Initial value
SS
HS
SL
HL
HS
2516
2516
2516
2516
3020
– 95 –
HL
2516
FU
SL
2516
FU
Smallest
change-
able unit
Rest time setup at the top position
of jump command
Setup of timeout period of input
command
Temporary stop control at sewing end
position
Valid/Invalid selection
Selection of XY feed synchronized
control/extension of main motor
Setup of intermediate presser lowering
speed
Setup of intermediate presser rising
speed
Selection of the presence of material
end detection control
Selection of the presence of inversion
device control
Y-axis position setup of inversion
device at automatic inversion
Setup of XY inching feed control/first
step time
Setup of XY inching feed control/
second step time
Setup of XY inching feed control/
max.speed