background image

 

 

Important Safety Instructions 

(This information should be saved for future reference.) 

 

CAUTION: This UPS has internal batteries which create a risk of electrical 
shock. Hazardous live parts inside this UPS are electrically energized from 
the batteries even when the input AC power is disconnected. 
 
CAUTION: There are no user serviceable parts inside this product. Do not 
remove the cover. The batteries are not to be replaced by untrained per-
sons.  
 
CAUTION: This product contains a non-isolated battery supply. The battery 
circuit is not isolated from the AC power input. Hazardous voltage may exist 
between battery terminals and ground. Remove watches, rings or other 
metal objects when dealing with potential electrical charges. Use tools with 
insulated handles.  
 
WARINGING: This product is intended for use in a controlled environment. 
Exposure to heat and / or moisture can cause damage or fire. The maximum  
ambient temperature in which this equipment may be safely installed is 104 
degrees F.  Do not expose the unit to significant physical impact or vibration.  
 
CAUTION: Do not dispose of any batteries, those included with this UPS or 
others, in fire. The batteries may explode. Do not open or mutilate any bat-
teries. Doing so may cause serious personal injury to skin and eyes. 
 
 

 
 

CAUTION 

This product has a dangerous amount of voltage. If the UPS power 
indicator is ON, the unit’s outlets may have a dangerous amount of 
voltage even if the UPS is not plugged into the wall.  
 
Install this product only indoors in a controlled environment free from 
electrically conductive particles.  
 
Install only near an easily accessible power outlet. Locate connected 
equipment near the UPS. Disconnect the UPS by removing the 
power cord and turning off the power button when safe access to the 
UPS is desired.  
 
All service must be conducted by trained personnel who have ac-
cess to this document.  

Summary of Contents for SL 350

Page 1: ...Slim Line UPS 350 VA 200 Watts SL 350 April 2017 Owner s Manual ...

Page 2: ...xposure to heat and or moisture can cause damage or fire The maximum ambient temperature in which this equipment may be safely installed is 104 degrees F Do not expose the unit to significant physical impact or vibration CAUTION Do not dispose of any batteries those included with this UPS or others in fire The batteries may explode Do not open or mutilate any bat teries Doing so may cause serious ...

Page 3: ... addition to battery power support the SL 350 provides 312 Joules of pro tection from AC power surges and spikes The SL 350 is designed to be used with a detachable power cord A three foot cord with a right angle plug is provided with the unit Should a different length or style of cord be needed for a particular installation or application one can be purchased at large and installed into this UPS ...

Page 4: ...harges its batteries while it is connected to AC utility power and the power switch is on Connecting and Powering Loads Plug equipment to be powered by the SL 350 into output receptacles on the UPS That equipment will not receive power unless the UPS is turned on To turn it on push the On Off power button When pushed again that button will also turn off power to the outlets Condition Visual LED Au...

Page 5: ...ully charged Allow the unit to charge for eight hours without a load on the UPS Make sure the power button has been pushed to turn on the unit If neither step solves the problem contact Juice Goose Battery Run Time Is Short The strength of the battery power supply can be tested by unplugging the unit from the wall while a load of a known size is con nected The SL 350 should provide power for at le...

Page 6: ... Style 18650 Quantity 8 Run time 6 mins full load 14 mins half load Surge Protection 312 Joules Line Neutral Physical Dimensions inches 6 9W x 8 5D x 1 25H Weight lbs 3 4 Line Cord provided 3 foot C13 IEC to 5 15P right angle NEMA Receptacles 3 x 5 15R NEMA Environment Temperature 32 to 104 degrees F Humidity 0 to 90 RH Altitude 11 500 feet over sea level Certification UL 1778 cTUVus FCC and RoHS ...

Page 7: ...the creation production and distribution of these products be liable for any damages including any lost prof its lost savings or other direct indirect special incidental or consequential charges even if JUICE GOOSE or an authorized JUICE GOOSE dealer has been advised of the possibility of such damage or any claim or claims by other parties In particular JUICE GOOSE shall have no liability for any ...

Page 8: ...8 Contact Information 7320 Ashcroft Suite 104 Houston Texas 77081 info juicegoose com 713 772 1404 ...

Reviews: