Diagnostics

Version Check

Enter the Diagnostic mode by pressing the 

MENU and RECALL keys simultaneously. 

The  first  diagnostic  screen  shows  the 

version  of  code  loaded  into  the  gun.  If 

no  action  is  taken  within  two  seconds, 

the  version  screen  clears,  and  the  gun 

reverts to radar mode.

Fork Mode

Press  the  MENU  key  while  the  version 

is  displayed  to  advance  to  the  Fork 

Diagnostic.  The  radar  is  automatically 

armed  with  no  holdover,  so  the  speed 

display shows just what the radar sees. 

A tuning fork with known frequency can 

be  used  during  this  diagnostic  to  verify  basic  radar  speed  acquisition  and 

accuracy. If no action is taken within one minute, the fork screen clears, and 

the gun reverts to radar mode.

0.0.0       

    

   

 

 

JU9S

 

AUTO
LOBATRIG
PEAK

FORK       

    

   

 

         

88

 

AUTO

LOBATRIG
PEAK

26

Summary of Contents for Pro-Sports R2000

Page 1: ...OWNER S MANUAL Instructions for JUGS Pro Sports Digital Radar Part No R2000 SAVE THIS MANUAL...

Page 2: ...y not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Any changes or modifications not expressly approved b...

Page 3: ...Angle Errors 12 Controls and Indicators 13 9 Pin Port Connector 14 Option Menu 15 Stopwatch Feature 19 Recommended Settings 20 Power Information 21 Interference Problems 23 Radar Accessories 24 Servi...

Page 4: ...S radar converts the reflected microwave signals into a digital stream of data The gun s own computer then processes this data stream using sophisticated programming to interpret filter and measure th...

Page 5: ...dar are listed below If you are missing any parts or if you would like to upgrade your package contact JUGS Sports at 1 800 547 6843 JUGS Pro Sports Radar K Band Radar Gun R2000 6 AA Nickel Metal Hydr...

Page 6: ...gun simply do the following 1 Turn the gun ON by pressing the red ON OFF button 2 Squeeze the trigger to begin transmitting Operator Menu Operator Menu For the quick start instructions above we have p...

Page 7: ...capture the speed of the object at its maximum distance Ball Sports Range For carnival or fundraising settings simply press the select button to change from 3 down to 1 The 1 setting is ideal for clo...

Page 8: ...wo times You will see the word Roll and then either Off or On Press the select button to toggle between On and Off Unit of Measure The JUGS Sports Radar is equipped with both the English MPH and metri...

Page 9: ...the recall mode by pulling the trigger at any time or by stepping through all stored recall speeds and pressing the RECALL key once more MODE BUTTON Trigger Mode Trigger mode is a manual operation The...

Page 10: ...Most activities will be able to utilize this target type Carnival Carnival and fundraising activities generally occur within close quarters Changing the range for this target type decreases the gun s...

Page 11: ...target type for tennis do the following Press the menu button and then the menu and mode button simultaneously to enter the option menu The first upper left window will indicate LOW Press the menu bu...

Page 12: ...k objects moving directly at or away from the gun Clocking at an angle with a stationary radar gun results in angle error and the gun displays a speed that is LOWER than the actual speed For accurate...

Page 13: ...erline of a tennis court In this manner the gun will capture serve and court shot speeds from either end of the court JUGS Pro Sports Radar WARNING Do not attempt to catch a thrown or struck ball and...

Page 14: ...Calculating Angle Errors Cosine Angle Error Chart 0 Degrees 5 Degrees 10 Degrees 15 Degrees 30 Degrees 45 Degrees 90 Degrees 0 Error 0 4 Error 1 5 Error 3 4 Error 13 4 Error 29 3 Error 100 Error 25 0...

Page 15: ...en operating or Range 3 2 1 when in menu ROLL Indicates the roll down feature is on and is to be displayed in the upper right window AUTO Is on when gun is in AUTO mode TRIG Is on when gun is in TRIG...

Page 16: ...and stored The 9 Pin D Connector has the following pinout Pin 1 is on the top right and Pin 9 is on the bottom left Controls and Indicators 1 AUX INPUT Stopwatch trigger input or remote transmit inpu...

Page 17: ...ory default 1 Low Speed LOW OFF 5 10 15 20 30 50 2 Resolution RES onES tnth 3 Target Type TARGT bALL cArn tEnn 4 Aux TriggerFunction AUX OFF StoP trig 5 Stopwatch Mode STOP Std LAP SPLt 6 Cosine Angle...

Page 18: ...N MENU All 8 s will briefly flash in the message and main windows to indicate the change of menu Press the MENU key to step through each of the features The SELECT key changes the setting once a featu...

Page 19: ...ct onES to display speed in whole units as 25 MPH or tnth to display speed with tenths as 25 4 MPH Target Type The target types available on the JUGS Pro Sports radar are BALL for ball sports CARN for...

Page 20: ...1 Message Termination Cr Carriage Return only 0x0D Only if format A CrLF Carriage Return Line Feed 0x0D 0x0A u Cr units followed by Carriage Return e g MPH 0x0D u CL units followed by Carriage Return...

Page 21: ...turn to radar mode press and hold the red button Stopwatch Timer Modes The default setting for the stopwatch is the standard timer Standard Timer This timer is useful as a running time clock or for su...

Page 22: ...can experiment with the Range setting depending on what motion and what rides are around the gun Menu Target Type Carnival Option Low Speed 30 MPH 50 KPH Option Range 1 To mask other Operator nearby...

Page 23: ...orts radar Using alkaline batteries may damage the JUGS Pro Sports radar and will void the warranty External To power the JUGS Pro Sports radar continuously you will need the optional 12V DC Cigar Cab...

Page 24: ...11 Hours Low Battery Warning The LOBAT icon blinks when the battery runs low The JUGS Pro Sports radar operates for a short time after this Operation is disabled when the battery voltage falls to an e...

Page 25: ...wever a loss of sensitivity can be subtle For example a common situation occurs when a large number of baseball scouts operate many radar guns in close proximity A loss of sensitivity can cause the ra...

Page 26: ...adar to assist you with all your radar needs PS Radar Wall Charger R2001 replacement PS Radar 12V Cigar Cable R2002 Allows continuous power to the radar gun via a cigar type adapter PS Radar Power Dat...

Page 27: ...nserted correctly into the chamber Next charge the batteries for a full 12 hours If the problem continues try a volt meter to determine if the batteries are producing at least 7 5 volts If not you may...

Page 28: ...ork Mode Press the MENU key while the version is displayed to advance to the Fork Diagnostic The radar is automatically armed with no holdover so the speed display shows just what the radar sees A tun...

Page 29: ...e due to dropping water salt improper voltage fire charging alkaline batteries in the unit attempted repairs or modifications by an unauthorized service agent or any other unusual treatment Voltage Mo...

Page 30: ...Diode Power Output 5 Milliwatts Nominal The JUGS Pro Sports radar complies with Part 15 of the FCC rules FCC ID IBQACMI005 GENERAL SPECIFICATIONS Product Type Stationary Doppler Radar Computer Process...

Page 31: ...tronic devices The data connector is on the side of the unit Serial Port Connector 9 PIN D CONN Mating Connector RS 232 or RS 485 Connector Signals 1 Aux Input 2 RS 232 TX 3 RS 232 RX 4 6 6 Volts OUT...

Page 32: ...message termination setting A Format Roll or Peak Resolution tenths Byte Description 1 Speed hundreds digit ASCII 2 Speed tens digit ASCII 3 Speed ones digit ASCII 4 Decimal Point 0x2E 5 Speed tenths...

Page 33: ...t to nonE ACSII spaces are used for leading zeros as above for the SPAC setting because Format bE uses fixed length fields The Message Termination setting affects format A When set to Cr default setti...

Page 34: ...32 Operator Notes 32...

Page 35: ...Operator Notes 33...

Page 36: ...duct or service please contact the manufacturer In the USA and Canada call toll free 1 800 547 6843 For International Orders call collect 0 503 692 1635 Our fax number is 1 503 691 1100 Visit our webs...