Cosine Angle:
You may adjust the cosine angle by ones from
0
to 45°. See
Calculating Angle Errors.
Serial Port Speed:
1200
, 2400, 4800, 9600, 19200, or 38400.
Serial Port Format:
Jugs
is the default. The “-“ (dash) is for no serial output,
the
A
format is for Selected Target Speed, and the bE format is for multiple
speeds.
Format A Speed:
(only for Format A) Roll or Peak speed.
Leading Zero:
Zero = 090
090.1
(only if format = A or bE)
Space = 90
90.1
None = 90
90.1
Message Termination:
Cr = Carriage Return only (0x0D)
(Only if format = A )
CrLF = Carriage Return & Line Feed (0x0D 0x0A)
u Cr = units followed by Carriage Return
— e.g., “MPH”0x0D
u CL = units followed by Carriage Return
& Line Feed — e.g., “km/h” 0x0D 0x0A
Peak Message Type:
Cont = continually streams peak speed
(Only if format = A)
Sing
= sends one peak speed message per
acquired target
Reset and Reset Confirmation:
The following steps reset the unit to the factory default settings:
•
RESET
no
– YES. Press the select button to toggle between no and YES.
•
SURE?
no
– YES. Press YES if you wish to reset the factory defaults. Pull
the trigger to exit and restore factory defaults.