Warranty and service
8
Warranty and service
To ensure the process operates successfully
for many years after first use, regular inspec-
tion and routine servicing of the system are
essential. Where home automation is con-
cerned, this is governed by DIN EN 806-5.
We recommend that you agree a service
contract.
A service contract is the best way of ensur-
ing correct operation even after the warranty
period has elapsed.
It is desirable that the regular maintenance
work and the supply of consumables, miner-
al solutions, salt or wear parts, etc. is per-
formed by the JUDO factory customer ser-
vice team or by an approved technical
service provider.
8.1
Inspection by the operator
every two months (visual in-
spection)
To retain your legal warranty rights, it is nec-
essary that an inspection be performed at
least every two months.
The operator checks:
– The salt filling level.
– The leak-tightness of the softening sys-
tem (escaping water).
– For damage to the water softener. De-
fective parts must be replaced by cus-
tomer service.
– Messages on the display.
Dependent on the consumed water volume,
the corresponding salt consumption must be
regularly monitored. If necessary, replenish
the regenerating salt (only use quality ac-
cording to DIN EN 973). When replenishing
the salt take appropriate hygiene measures.
Thus, for example, the salt packs should be
cleaned before use so that no impurities can
get into the salt dissolving container. The re-
generating salt must be shaken into the salt
dissolving container directly after undoing
the packaging. In doing so, ensure that the
salt dissolving container is not overfilled and
that after completing the work, it is again
carefully closed and sealed. Do not use par-
tial packs. The salt must only be stored in
clean and dry rooms.
8.2
Six-monthly maintenance
by the operator
In addition to the checks of the 2-month in-
spection, the operator must also check the
following every six months:
– Leak-tightness of the softener to waste
water connection.
No water must flow out of the waste wa-
ter hose (see fig. 8) in the operating po-
sition.
– Salt deposits inside the water trap.
Deposits or incrustations inside the wa-
ter trap must be removed so that the
waste water does not get blocked.
– Soft water hardness.
Checking is performed with a hardness
measuring instrument (in the scope of
supply).
8.3
Annual maintenance
by customer service
Once yearly, a service must be performed
by a licensed technical service provider or
the JUDO factory customer service team.
8.3.1 Message
“Maintenance/Service”
After an operating period of one year, the
water softening system signals the required
service. The following message is output to
the display:
After performing the maintenance, the mes-
sage is reset by pressing the <OK> key for
at least 5 s.
Maintenance/
Service req.
Summary of Contents for QUICKSOFT MEGA
Page 3: ...JUDO QUICKSOFT MEGA 3...
Page 13: ...JUDO QUICKSOFT MEGA 13 Operation 5 4 Menu structure Fig 6 Menu structure...
Page 22: ...22 JUDO QUICKSOFT MEGA Data sheet Fig 7 Electronic control unit with fault message relay...
Page 25: ...JUDO QUICKSOFT MEGA 25 Notes...
Page 26: ...26 JUDO QUICKSOFT MEGA Notes...
Page 27: ...JUDO QUICKSOFT MEGA 27 Notes...