Installation
INFO_NO_HEADER
If the installation is twisted, a func-
tioning of the device is not possible.
1
2
Fig. 3:
Rotary flange fitting
1
Profile flange seal
2
Flow direction arrow
3.3
Installation of the device
CAUTION
If no bypass valve is installed, a
shut-off valve must be installed
upstream and downstream of the
unit in order to interrupt the water
supply during installation, mainte-
nance, repair or malfunction of the
device.
Install the device in a vertical
position (± 5°); the connection
for waste water from backwash-
ing must be directed downwards.
Otherwise, water may escape and
cause water damage.
For the installation of the device
in domestic water piping, only use
the supplied built-in rotary flange
(see chapter 3.2).
The flange surface of the rotary
flange fitting must be upright!
For proper sealing the profile of
the profile flange seal must point
towards the rotary flange fitting
(see Figure 3: Rotary flange fitting,
page 10).
Fig. 4:
Attach and engage appliance
1
Insert screws
2
Turn clockwise to engage screws
10
JUDO JUKOMAT-LF-AT
1701431 • 2022/01