V:\Mark\AP-F6 Operation Manual.doc
7
JST
AP-F6 PNEUMATIC CRIMPING MACHINE
Step 2, Lower crimping die mounting
procedure.
Position the conductor anvil in the
lower crimping die holder, mount the
insulation anvil in front of conductor
anvil, and secure with the cap screw
provided, whilst simultaneously
pushing down on the anvils to ensure
that they are correctly seated in the
holder.
Step 3, Stripper mounting
A stripping blade is required to ensure
that the terminal is removed from the
crimping punches after the completion
of the crimping operation. The
Stripping blade works by ' wiping ' the
terminal from between the blades.
The stripper is mounted on a backing
plate, part no F3-4132, which is in turn
mounted on a bracket, part no 2108-
4117-1, and is positioned equally
distant between the conductor and
insulation punches, ensuring that it
does not touch either of the punches.
The stripper, backing plate and
bracket are all secured by cap head
screws which should be securely
fastened upon completion of the
adjustment.