background image

©JRI 

 

 

 

 

I.

 

PRESENTATION OF THE SPY IP 

1)

 

Presentation 

The  SPY  IP  has  been  designed  to  monitor  and  record  simultaneously  up  to  4  different 
parameters from either analog, logical, or digital sensors. The device communicates with the 
Sirius Operating Software over the Ethernet network. 
 

2)

 

Equipment 

1 SPY IP recorder 
1 Wall mounting bracket  
1 Ethernet cable 
1 Power supply for VDC versions 
 

3)

 

Symbols 

 

RECYCLING

:  do  not  throw  into  the  household  waste  bin.  Comply  with  local 

regulations for recycling and waste disposal. 

 

POWER  SUPPLY

:  this  device  is  powered  with  9VDC-650mA  from  an  230  VAC 

adapter or from the Power over Ethernet connection (POE). Comply with safety 
rules  regarding  electricity.  Make  sure  that  the  electrical  installation  complies 
with current regulations. 

 

 

CE  MARKING:

  this  device  complies  with  EU  legislation  for  electric  security, 

inflammability,  disturbing  radiation  emission  and  immunity  to  surrounding 
electric disturbances 

 

II.

 

 INSTALLATION INSTRUCTIONS 

 

1)

 

Location 

 

The SPY IP recorder features a backlit touchscreen. It should be placed:  

 

at approx. 1.5m above the ground in order to be able to see the touchscreen without 
difficulties, 

 

in a central position to the measurement points taking into account the length of the 
probes, 

 

within reach of a Power Ethernet socket. 

Also  provide  for  a  power  outlet  according  to  safety rules  and  legislation  relatively  close to 
the powered devices.  

 
 

Warning: 

For  use  with  POE  power,  the  source  of  this  power  must  be  strictly  in  accordance  with 
safety requirements. 
In general, JRI disclaims all liability with respect to damages arising out of or in connection 
with any use other than those recommended in this manual. 

 
 
 

Summary of Contents for SPY IP 4

Page 1: ...USER MANUAL SPY IP 10486F...

Page 2: ...Start modes 10 c Zone 4 Alarm Thresholds 10 d Zone 5 Off Modes 10 e Main Menu 10 4 BACKLIGHT COLOURS 10 5 SCREEN NAVIGATION 11 a Main menu 11 b Menu Configuration 11 c Device Status Menu 12 d Alarm M...

Page 3: ...omplies with current regulations CE MARKING this device complies with EU legislation for electric security inflammability disturbing radiation emission and immunity to surrounding electric disturbance...

Page 4: ...guration information from the DHCP server If the UDP broadcast is not allowed you must carry out a manual installation on Sirius Storage using the IP address provided by the DHCP server and the serial...

Page 5: ...twork UDP packets are never transmitted and you must carry out a manual installation If the manual installation fails make sure that the internal serial number matches the serial number printed on the...

Page 6: ...3 Declare in Sirius measures RH on channels 2 and or 4 c Identification of the connectors d Wiring Rear view of the connectors Probe 1 to 4 Ethernet Network RJ45 Modular connector Male plug end on the...

Page 7: ...JRI recommends using the cable with the reference number 00949 for connecting equipment which is not provided with a compatible socket f Battery backup Minimum battery backup time is 6 hours with a 3...

Page 8: ...e alone Humidity Measurement range resolution accuracy probe alone 40 C to 85 C 0 01 C 0 2 C from 20 C to 50 C 0 4 C outside 0 100 0 01 2 from 20 to 80 3 5 outside Current input 0 20 ou 4 20 mA measur...

Page 9: ...avoid damaging the touchscreen do not use sharp instruments and do not press hard 2 Touchscreen Description Channel ID Status of the device Measurement and start modes Channel number and alarm thresh...

Page 10: ...resholds High Pre Alarm High Alarm Low Pre Alarm Low Alarm d Zone 5 Off Modes Push Button Programmed stop delay Target value upward movement Target value downward movement e Main Menu Back to previous...

Page 11: ...r a pencil tip See Principle above Press the screen to access the main menu Back to measurement display a Main menu Select the desired zone by pressing the relevant icon b Menu Configuration The SPY I...

Page 12: ...dgment from the touchscreen Spy IP The action will be authorized and stored by Sirius The password change will just be made from Sirius Default IP Spy has 1 Profile Administrator mdp 1111 V HOW THE SP...

Page 13: ...mmed via Sirius are Immediate Pushbutton Programmed start delay Target value Change of state of one of the other channels a Immediate default mode in Sirius The channels set with this start mode will...

Page 14: ...art recording when it has reached its target value taking into account the direction of the variation upward or downward movement If a channel has no target value it is considered as being configured...

Page 15: ...t got the rights the request will be rejected and the channel will continue recording d Target value This off mode can only be used and configured channel by channel The channel will stop recording w...

Page 16: ...re alarm then the backlight colour will be the same for all the channels according to the most important even In this case it will be RED The threshold alarms can be either instantaneous or continuous...

Page 17: ...hout prior notice IX MAINTENANCE CONTRACT With our maintenance contract you will benefit for a minimal period of 2 years from the following advantages material verification once or twice a year warran...

Reviews: