4-9
4
4.6 Countermeasure
If the equipment does not operate normally even following procedure is performed, please consult
JRC service agent.
Take care not to touch any parts PC board.
Abnormal operation of IME
In case of the heavy fluctuation of the voltage or frequency of the power source, or thunderbolt
and etc., IME may not operate normally. In this case, please try following procedure (a). And
try procedure (b) when procedure (a) did not work.
(a) Set
POWER
switch to OFF, and confirm all of the LED lamps are lights out (it will takes
approximately 3 minutes) and set to ON again.
(b)
Press
RESET
button in the IME panel by the tip of narrow object (like extended clip,
φ
0.5mm).
Push until you feel the object clicks. (refer Fig. 4.6)
Five lamps (
POWER
lamp to
RECEIVE
lamp) lights in order, and starts blinking (it will takes
approximately 10 seconds). Turn on POWER switch with confirming these lamps are blinking.
The data, which are received message, call logging history and alarm history, memorized in IME are
cleared when RESET button is pushed. Saving important data to Floppy-Disk or USB Flash Memory is
highly recommended (Prepare optional DTE, Floppy-Disk Drive (for DTE (NDZ-127C1)), and JUE-85
instruction manual).
Procedure (b)
Push the
RESET
Button with a stick of
wire like extended clip.
The depth of the hole is approximately
1cm. So, use the wire 2cm or more.
Procedure (a)
Set
POWER
switch to OFF and set to
ON again.
NOTE
Fig. 4.6 Reset of IME
Summary of Contents for JUE-95SA -
Page 2: ......
Page 14: ...1 2 ...
Page 22: ...2 8 2 4 3 Printer NKG 800 Fig 2 4 3 Pinter ...
Page 24: ...2 10 2 5 2 EME NAF 253SA Fig 2 5 2 EME NAF 253SA Unit mm Mass Approx 2 4 kg Color N9 ...
Page 25: ...2 11 2 2 5 3 IME NTF 782SA Fig 2 5 3 IME Unit mm Mass Approx 1 3kg ...
Page 26: ...2 12 2 5 4 JB MPBC40613 Fig 2 5 4 JB Unit mm Mass Approx 1 1kg ...
Page 31: ...2 17 2 2 6 2 DTE Keyboard NDF 368 Fig 2 6 2 DTE Keyboard NDF 368 Unit mm Mass 0 4kg ...
Page 32: ...2 18 2 6 3 DTE Display NDZ 227 ...
Page 33: ...2 19 2 2 6 4 DTE Keyboard NDF 369 Fig 2 6 4 DTE Keyboard NDF 369 Unit mm Mass 0 4kg ...
Page 64: ...4 12 ...
Page 66: ...5 2 ...
Page 68: ...6 2 ...
Page 69: ......