2-12
2.4. Input/Output Specifications
This section explains the signals to be connected to connectors in the power circuit
CBD-1702A.
2.4.1. SCANNER (J2)
SCANNER (J2) is used for connection with the scanner unit.
PIN
NAME
DESCRIPTION
APPLICATION
1 MOTOR-
2 MOTOR-
3 TRX-
4 MOTOR+
5 MOTOR+
6 TRX+
7 GND
8 +12V
9 MTR-
RS485
10 MTR+
RS485
11 BZE
12 BZ
470ohm
pull-up
13 BPE
14 BP
470ohm
pull-up
15 TRGE
16 TRG
180ohm
input
17 VDE
18 VD
50ohm
input