Current Measuring Depth Setting
The depth of the measured current is set. I
t set on all screens except fish finder screen.
1) "Setting of the depth of the current measurement layer" menu (*1) is displayed by the [DEPTH]
key.
2) Each depth of five layers of A-E that displays the current by the menu is set.
Ex.) Setting of A Layer: "30" is input with numeric key after A layer is selected by
▼▲
key
when the measurement depth of A layer is set to 30m, [ENT] key is pushed, and it fixes.
3) Similarly, B-E layer is set.
4) The depth menu is ended pushing [depth] key again.
3.1.4
Fish Finder Display Range Setting
The range of depth, sensitivity [GAIN], and the bubble cancellation [STC] etc. of the fish finder
screen are set.
* It is not possible to set it on screens other than the fish finder screen.
1 Selecting display beam
Which screen is displayed among one screen display, two screen display, and four screen displays
is selected.
In one screen display, the direction of the displayed beam is selected from the following four
directions by menu (*2).
Beam Direction: Fore Starboard/Fore Port/After Starboard/After Port
The direction of the displayed beam is selected from the following three directions by menu (*2) on
two screen display.
Beam Direction: Fore/Starboard/Port
2 Setting Depth Range
1) After numeric key (1-9,0) on the keyboard is pushed, it changes within the depth range set to each
key.
2) A set value of ten numeric keys and a set value within the depth range can be confirmed by "Fish
finder screen depth range setting" menu. A set menu is displayed by the [DEPTH] key. (*3)
3 Adjustment of Sensitivity [GAIN]:
Adjustable at the range of 0.0-10.0
The receiving sensitivity of the fish finder screen is adjusted with the [GAIN] knob of the keyboard.
Sensitivity rises by the display under the left of the screen, and the numerical value large as for the
sensitivity value.
4 Adjustment of Sensitivity in the shallow water [STC]
: Adjustable at the range of 0.0-10.0
The noise removal under surface of the water level is adjusted with the [STC] knob of the keyboard.
The level by which the bubble is erased is displayed lower the left of the screen. The range of depth
to remove the noise broadens when the numerical value is large.
3.1.5
Power OFF
The [PWR] key and the [OFF] key are pushed at the same time for about one second.
It sounds with [pi--pi], and the power supply enters the state of determination.
*It takes about ten seconds until the power supply cuts completely. (*4)
* Push the [PWR]
key and the [OFF] key at the same time for about ten seconds or more when you do not determine
the power supply by any chance. It compulsorily becomes power supply determination.
*1 Depth setting in current measurement layer: Refer to 4.2.3 “Current Measurement Layer Depth Setting”.
*2 Selection of Beam Direction: Menu/Picture Setting/Fish Finder It sets in the screen.
*3 Fish Finder Screen Setting Menu of Depth Range: It is displayed that the [DEPTH] key is pushed by the fish finder screen
displayed.
*4 When the [PWR] key is pushed at once after the power supply cuts, it is likely not to start normally.
Operation Procedure
Operation Procedure
End
▼
▼
▼
Summary of Contents for JLN-650
Page 2: ...ii...
Page 18: ......
Page 20: ......
Page 21: ...1 1 1 Overview...
Page 22: ...1 2...
Page 29: ...1 9 1 Fig 1 4 2 NCH 603E Keyboard Outline Unit mm...
Page 33: ...1 13 1 Fig 1 4 5 1 NKF 775 Transducer Outline...
Page 34: ...1 14 Fig 1 4 5 2 NKF 780 Transducer Outline Unit mm BOW...
Page 37: ...2 1 2 Name and Functions...
Page 38: ...2 2...
Page 60: ......
Page 61: ...3 1 3 Operation Method...
Page 62: ...3 2...
Page 77: ...4 1 4 Operation...
Page 78: ...4 2...
Page 120: ......
Page 121: ...5 1 5 Measurement Alarm...
Page 122: ...5 2...
Page 125: ...6 1 6 How to See Display...
Page 126: ...6 2...
Page 132: ......
Page 133: ...7 1 7 Confirming the Operation of Equipment...
Page 134: ...7 2...
Page 145: ...8 1 8 Maintenance and Check...
Page 146: ...8 2...
Page 149: ...9 1 9 Trouble and After sales Service...
Page 150: ...9 2...
Page 153: ...9 5 9...
Page 160: ...9 12...
Page 161: ...10 1 10 10 Disposal...
Page 162: ...10 2...
Page 164: ......
Page 165: ...11 1 11 Specifications...
Page 166: ...11 2...
Page 170: ......
Page 171: ...12 1 12 Others...
Page 172: ...12 2...
Page 184: ...12 14 12 2 Connection Diagram JLN 650 Connection Diagram...
Page 185: ...12 15 12 JLN 652 Connection Diagram...
Page 186: ...12 16 12 3 Spare Parts List...
Page 187: ...12 17 12 JLN 652 1 1 7ZXNA3002 JLN 652 1 1 7ZXNA3002...
Page 188: ......
Page 189: ......