6. Maintenance & Check 54
Displaying Alert Log
・
Make ALERT LOG a yellow display, press or the [ENT] key, and
last 20 memorized alert histories are displayed.
・
Each alert log displays alert occurred position (position data need),
date/month/year, time, alert No. and alert status.
Alert No. is from 01 to 13. The No. meaning is shown in page 24.
Alert status has “A: alert is still lasting” and “V: cleared alert
condition”.
・
When the [CLR] key is pressed, it returns to the maintenance menu.
Outputting Alert Log
・
Make ALERT LOG OUT a yellow display, press or the [ENT] key,
and
selects it from the following, set content.
Set content
:
NORMAL/PRINTER/PC
NORMAL
:
last 20 memorized alert histories are output to the depth output port.
PRINTER
:
The alert history is displayed to the printer in the text.
The content to display is equal to “ALERT LOG".
When “PRINTER PORT OUT" of menu “COMMUNICATION"
is set to “PC", it becomes an error.
PC
:
All the memorized alert histories are output to the printer output port.
When “PRINTER PORT OUT" of menu “COMMUNICATION" is set to “PRINTER", it
becomes an error.
Deleting Alert Log
・
Make ALERT LOG DEL a yellow display, press or the [ENT] key, and
all the memorized alert histories
are deleted.
Position date time No. status
ALERT
Summary of Contents for JFE-680 -
Page 2: ......
Page 9: ...External View External View vii NO ALERT ...
Page 18: ...1 5 System Configuration 1 Introduction 6 alert alert alert alert alert alert alert ...
Page 54: ...5 1 Installing the Recorder Unit Flush Mount Equipment Figure 3 1 5 Installation 42 Unit mm ...
Page 55: ...Wall Mount Equipment Figure 3 2 5 Installation 43 Unit mm ...
Page 57: ...NKF 345 5 Installation 45 ...
Page 58: ...NKF 392C 5 Installation 46 ...
Page 59: ...NKF 393 5 Installation 47 ...
Page 60: ...NKF 394 5 Installation 48 ...
Page 61: ...NKF 396 5 Installation 49 ...
Page 84: ......
Page 85: ......