(3)
Saving data to compact flash memory
Procedure for saving data in compact flash memory:
a)
Setting of an output destination
Press the 4
SET
key on the scan test screen, and set "CF (text)" or "CF (binary)" for
"External output" on the parameter setting screen.
b)
Setting of a data number
An arbitrary number can be assigned to scanned data by setting the number for "Data
No." on the parameter setting screen. The data number (Data No.) is incremented each
time data is saved.
c)
Saving of sense test data
If the 13
OUTPUT
key is pressed while a scan test is stopped on the scan test screen,
data from scan testing can be saved to a compact flash memory card.
The file name of saved data is determined as follows:
B 1 2 3 0 4 5 0 . 0 0 1
Data No.
Scan test time: The first 2 digits indicate hours; the last 2 digits
indicate minutes.
Scan test date
Scan
test month month: A, B, and C stand for October, November, and
December, respectively.
Save format: T stands for text format; B stands for binary format.
d)
Confirmation of data saved
Press the 12
CF
button. The screen will be switch to the CF control screen shown in
Figure 3-17 where you can check whether data has been saved. On the CF control
screen, you can also display the thumbnail images of saved data, read/delete
data, and initialize the compact flash memory. For details, see "Section 3.7 CF
Control Screen."
‑ 60 ‑
Summary of Contents for Handy Search NJJ-95B
Page 1: ...Handy Search Instruction Manual...
Page 8: ...Appearance of the NJJ 95B vii...
Page 21: ...Rear view Units in trigonometry mm 9...
Page 24: ...8 14 15 Figure 2 2 Side View 16 17 14 18 Figure 2 3 Rear View 12...
Page 73: ...Display of thumbnails Figure 3 17 CF Control Screen 61...
Page 83: ...B Terminals ACharge confirmation mark Figure 3 22 Battery Pack 71...
Page 85: ...Shutter Charge lamp Figure 3 23 Battery Charger 73...
Page 96: ...Concrete Rebar D 75mm L 75mm D 75mm Difficult to implement 84...
Page 103: ...Dimensions Weight About 149 W x 147 H x 216 D mm Approximately 1 1kg 91...