The PERISTALTIC Series of metering pumps require a minimal amount of maintenance to 
achieve optimal performance.  Periodically check the squeeze tube for cracks, deterioration, 
or swelling.  The squeeze tube will typically need to be  replaced about every 6 months 
(chemical compatibility and duty cycle can cause this interval to vary).  NOTE: squeeze tubes 
are NOT a warranty item.  

VERY IMPORTANT: When replacing squeeze tubes, DO NOT TWIST THE TUBES WHEN 
FITTING THEM AROUND THE ROLERS.  
Insert them so they remain flat in the same plane.  
(The writing on the tubes should be inline on both sides of the rollers.) 

Appling lube to the squeeze tube once a month can extend the life of the tube, minimize wear 
on other contacting parts, and promote smoother pump operation. Use Knight Tube Lube (P/
N 245-4-SQZLUBE) or an equivalent silicone-based lubricant. 

 

1.  Remove the faceplate of the pump. 

 

2.  Apply a thin bead of Tube Lube to the inner surface (the side that the rollers contact) 

 

of the squeeze tube between the 9 o’clock and 3 o’clock positions.  Avoid getting the 

 

lube near the pinch points where the bottom of the faceplate grips the tube. 

 

3.  Put the faceplate back on the pump 

Activate the pump under normal conditions—the lubricant will be evenly distributed as the 
pump rotates. 

 

 

CAUTION: To avoid severe or fatal shock, always disconnect main power when 

servicing the unit. 

MAINTENANCE 

Summary of Contents for 290-TIME-1

Page 1: ...T 4 A Using the Meter 4 III MENU OPERATION 5 A Menu Hierarchy 5 B Main Menu Screens 6 C Pump Controls for P models only 7 D Setup Options 8 IV APPENDIX 9 A Maintenance 9 B Parts List 10 Check for the...

Page 2: ...you shorten this wire remove all shielding from the ends of the twisted pair and put tape around the ends At no time should the shielding be grounded 4 Connect the 120VAC power source plug into the 1...

Page 3: ...e length of time that the operator has designated in TIMER1 and TIMER2 PUMP 1 PUMP 2 PUMP OUTPUT Only in Pump Control Versions The TIME P3 models come with either one or two peristaltic pumps When the...

Page 4: ...ree 3 seconds a flashing cursor will appear allowing for changes to be made In this mode the SELECT key moves your cursor right and the CHANGE key advances the selected value by one Once you have set...

Page 5: ...tal 3 Prime Pump if either pump is enabled IF PUMP 1 IS ENABLED 4 Preset 1 5 Preset 1 Count Left 6 Timer 1 7 Timer 1 Count Left 8 Cycle Count 1 IF PUMP 2 IS ENABLED 9 Preset 2 10 Preset 2 Count Left 1...

Page 6: ...nu screen 3 PRIME PUMP if either pump is enabled Holding SELECT on this screen will allow you to enable disable both pumps separately Press SELECT to switch between PUMP 1 and PUMP 2 When a pump is en...

Page 7: ...ed to set the amount of time in seconds the corresponding pump should run The number of seconds in PRESET COUNT LEFT will count to zero 0 activating the corresponding pump for the amount of time in se...

Page 8: ...er than closing for the period of time set in TIMER 14 5 KEYED ON OFF This screen allows you to enable or disable the keyed on off function If ENABLED holding the CHANGE key for three 3 seconds enable...

Page 9: ...es of the rollers Appling lube to the squeeze tube once a month can extend the life of the tube minimize wear on other contacting parts and promote smoother pump operation Use Knight Tube Lube P N 245...

Page 10: ...ROLLER FOR PERISTALTIC UNITS 245 4 ROLLER FACEPLATE FOR PERISTALTIC UNITS 245 4 FACEPLATE ROLLER TUBE PUMP HOUSING 245 4 PMPBODY DELIVERY TUBING 20 ROLL 245 4 PLYTB20 Polyethylene 1 4 OD rigid wall tu...

Page 11: ...ment be subrogated to exclusive distributors or manufacturers who shall assume all or portions of the liability associated with warranty costs This warranty may be modified wholly or in part at any ti...

Reviews: