JP Tech 290-TIME-1 User Manual Download Page 10

 10 

 

ITEM   

 

 

 

 

 

 

 

 

PART NUMBER

 

ELASTIC SQUEEZE TUBE   

 

 

 

 

 

245-4-ELSQZTUB 

 

(Standard with unit. Good for weak to strong alkalis, weak to medium acids.) 

THERMISTANT SQUEEZE TUBE   

 

 

 

 

245-4-TMSQZTUB 

 

(Has superior acid-resistant and alkali-resistant qualities.) 

FLUORO-VITON SQUEEZE TUBE  

 

 

 

 

245-4-FVSQZTUB 

 

(Good for strong solvents and acids.) 

SQUEEZE TUBE LUBRICANT 

 

 

 

 

 

245-4-SQZLUBE 

100 RPM/24 VDC PERISTALTIC GEARMOTOR  

 

 

245-4-GEARMOTOR-FV 

ROLLER FOR PERISTALTIC UNITS  

 

 

 

 

245-4-ROLLER 

FACEPLATE FOR PERISTALTIC UNITS 

 

 

 

 

245-4-FACEPLATE 

ROLLER / TUBE  PUMP HOUSING 

 

 

 

 

245-4-PMPBODY 

DELIVERY TUBING—20’ ROLL   

 

 

 

 

245-4-PLYTB20 

 

(Polyethylene 1/4’ OD, rigid wall tubing) 

DELIVERY TUBING—50’ ROLL   

 

 

 

 

245-4-PLYTB50 

DELIVERY TUBING—100’ ROLL   

 

 

 

 

245-4-PLYTB100 

PERISTALTIC HINGE 

 

 

 

 

 

 

245-4-HINGE 

PICK UP TUBE 

 

 

 

 

 

 

 

245-4-PICKUP 

 

NOTE:  CHECK YOUR SQUEEZE TUBES PERIODICALLY FOR INTEGRITY (ABLE TO EXPAND AFTER 

BEING SQUEEZED BY THE ROLLERS).

 

 

ORDER PARTS 

PHONE:   

262-642-7671 

FAX:   

262-642-7681        

E-MAIL: 

[email protected] 

MAIL:  

JP TECH, INC. 

 

 

P.O. Box 863 

 

 

East Troy, WI 53120 

 

 

USA 

WEB:   

JPTech.com 

PARTS LIST 

Summary of Contents for 290-TIME-1

Page 1: ...T 4 A Using the Meter 4 III MENU OPERATION 5 A Menu Hierarchy 5 B Main Menu Screens 6 C Pump Controls for P models only 7 D Setup Options 8 IV APPENDIX 9 A Maintenance 9 B Parts List 10 Check for the...

Page 2: ...you shorten this wire remove all shielding from the ends of the twisted pair and put tape around the ends At no time should the shielding be grounded 4 Connect the 120VAC power source plug into the 1...

Page 3: ...e length of time that the operator has designated in TIMER1 and TIMER2 PUMP 1 PUMP 2 PUMP OUTPUT Only in Pump Control Versions The TIME P3 models come with either one or two peristaltic pumps When the...

Page 4: ...ree 3 seconds a flashing cursor will appear allowing for changes to be made In this mode the SELECT key moves your cursor right and the CHANGE key advances the selected value by one Once you have set...

Page 5: ...tal 3 Prime Pump if either pump is enabled IF PUMP 1 IS ENABLED 4 Preset 1 5 Preset 1 Count Left 6 Timer 1 7 Timer 1 Count Left 8 Cycle Count 1 IF PUMP 2 IS ENABLED 9 Preset 2 10 Preset 2 Count Left 1...

Page 6: ...nu screen 3 PRIME PUMP if either pump is enabled Holding SELECT on this screen will allow you to enable disable both pumps separately Press SELECT to switch between PUMP 1 and PUMP 2 When a pump is en...

Page 7: ...ed to set the amount of time in seconds the corresponding pump should run The number of seconds in PRESET COUNT LEFT will count to zero 0 activating the corresponding pump for the amount of time in se...

Page 8: ...er than closing for the period of time set in TIMER 14 5 KEYED ON OFF This screen allows you to enable or disable the keyed on off function If ENABLED holding the CHANGE key for three 3 seconds enable...

Page 9: ...es of the rollers Appling lube to the squeeze tube once a month can extend the life of the tube minimize wear on other contacting parts and promote smoother pump operation Use Knight Tube Lube P N 245...

Page 10: ...ROLLER FOR PERISTALTIC UNITS 245 4 ROLLER FACEPLATE FOR PERISTALTIC UNITS 245 4 FACEPLATE ROLLER TUBE PUMP HOUSING 245 4 PMPBODY DELIVERY TUBING 20 ROLL 245 4 PLYTB20 Polyethylene 1 4 OD rigid wall tu...

Page 11: ...ment be subrogated to exclusive distributors or manufacturers who shall assume all or portions of the liability associated with warranty costs This warranty may be modified wholly or in part at any ti...