8
MENU OPERATION
Setup Options
14.1 RELAY 1 / 14.2 RELAY 2
This screen is used to select what kind of device you are
controlling. You can choose between a PUMP or to
DISABLE one or both of the relays. Enabling either of the
relays will allow access to the corresponding PUMP and
TIMER menus.
14.3 DISPLAY MODE
Holding SELECT will allow you to toggle between seconds,
minutes, or hours as the default unit of time on the
meter.
14.4 ONE SHOT MODE
One Shot Mode allows you to close the dry contact for a
burst, rather than closing for the period of time set in
TIMER.
14.5 KEYED ON/OFF
This screen allows you to enable or disable the keyed on/
off function. If ENABLED, holding the CHANGE key for
three (3) seconds enables the timer. For most users, this
should remain DISABLED.
14.6 SW DEBOUNCE
When the contacts of a switch close, sometimes they can
bounce, so that a single press can appear like multiple
presses. If this is happening, enabling Switch Debounce
will ignore quick subsequent presses of the switch
detected within the second range input here. Switch debounce is preset at the factory, and
usually does not need to be changed.
RELAY1
DISABLED
KEYED ON/OFF
DISABLED
ONE SHOT
DISABLED
DISPLAY MODE
SECONDS
SW DEBOUNCE
01