JP Tech 290-TIME-1 User Manual Download Page 1

 1 

TIME BASED METERS 

PUMP CONTROLLERS 

MODELS 

290-TIME-1 
290-TIME-P1 

290-TIME-P3 

CONTENTS 

I. INSTALLATION  

 

 

 

 

 

 

 

 

 

 

 

A. Step-by-Step Guide  

 

 

 

 

 

 

 

 

 

B. Model Overview 

 

 

 

 

 

 

 

 

 

II. QUICK START  

 

 

 

 

 

 

 

 

 

 

 

A. Using the Meter 

 

 

 

 

 

 

 

 

 

4 

III. MENU OPERATION 

 

 

 

 

 

 

 

 

 

 

A. Menu Hierarchy 

 

 

 

 

 

 

 

 

 

 

B. Main Menu Screens 

 

 

 

 

 

 

 

 

 

C. Pump Controls (for P models only)   

 

 

 

 

 

 

D. Setup Options 

 

 

 

 

 

 

 

 

 

IV. APPENDIX 

 

 

 

 

 

 

 

 

 

 

 

 

A. Maintenance   

 

 

 

 

 

 

 

 

 

 

B. Parts List 

 

 

 

 

 

 

 

 

 

 

10 

Check for the latest manual updates at 

JPTech.com 

USER MANUAL 

JP Tech, Inc. •  PO Box 863 •  2286 Church Street •  East Troy •  WI •  53120 

Phone: (262) 642-7671 •  Fax (262) 642-7681 

REVISED 6/30/16 

Summary of Contents for 290-TIME-1

Page 1: ...T 4 A Using the Meter 4 III MENU OPERATION 5 A Menu Hierarchy 5 B Main Menu Screens 6 C Pump Controls for P models only 7 D Setup Options 8 IV APPENDIX 9 A Maintenance 9 B Parts List 10 Check for the...

Page 2: ...you shorten this wire remove all shielding from the ends of the twisted pair and put tape around the ends At no time should the shielding be grounded 4 Connect the 120VAC power source plug into the 1...

Page 3: ...e length of time that the operator has designated in TIMER1 and TIMER2 PUMP 1 PUMP 2 PUMP OUTPUT Only in Pump Control Versions The TIME P3 models come with either one or two peristaltic pumps When the...

Page 4: ...ree 3 seconds a flashing cursor will appear allowing for changes to be made In this mode the SELECT key moves your cursor right and the CHANGE key advances the selected value by one Once you have set...

Page 5: ...tal 3 Prime Pump if either pump is enabled IF PUMP 1 IS ENABLED 4 Preset 1 5 Preset 1 Count Left 6 Timer 1 7 Timer 1 Count Left 8 Cycle Count 1 IF PUMP 2 IS ENABLED 9 Preset 2 10 Preset 2 Count Left 1...

Page 6: ...nu screen 3 PRIME PUMP if either pump is enabled Holding SELECT on this screen will allow you to enable disable both pumps separately Press SELECT to switch between PUMP 1 and PUMP 2 When a pump is en...

Page 7: ...ed to set the amount of time in seconds the corresponding pump should run The number of seconds in PRESET COUNT LEFT will count to zero 0 activating the corresponding pump for the amount of time in se...

Page 8: ...er than closing for the period of time set in TIMER 14 5 KEYED ON OFF This screen allows you to enable or disable the keyed on off function If ENABLED holding the CHANGE key for three 3 seconds enable...

Page 9: ...es of the rollers Appling lube to the squeeze tube once a month can extend the life of the tube minimize wear on other contacting parts and promote smoother pump operation Use Knight Tube Lube P N 245...

Page 10: ...ROLLER FOR PERISTALTIC UNITS 245 4 ROLLER FACEPLATE FOR PERISTALTIC UNITS 245 4 FACEPLATE ROLLER TUBE PUMP HOUSING 245 4 PMPBODY DELIVERY TUBING 20 ROLL 245 4 PLYTB20 Polyethylene 1 4 OD rigid wall tu...

Page 11: ...ment be subrogated to exclusive distributors or manufacturers who shall assume all or portions of the liability associated with warranty costs This warranty may be modified wholly or in part at any ti...

Reviews: