7.1 Quick operation

1

 Press over «TASK».

SETTINGS

PROGRAMMING

TASK

4

 Press over         .

HH:MM:SS DD/MM/YY   

22.9

 

ºC

SET

40.0

FLOW

80%

DURATION

SET --H--M

3

Set the temperature with        and 

(40ºC on the picture)

HH:MM:SS DD/MM/YY   

22.9

 

ºC

SET

40.0

FLOW

80%

DURATION

SET --H--M

HH:MM:SS DD/MM/YY   

22.9

 

ºC

SET

30.0

FLOW

80%

DURATION

SET --H--M

2

 Press over temperature display

(Frame changes to yellow color)

Notes:

In a similar way, hours and minutes of working time could be programmed.

The temperature set from this screen does not remain recorded once equipments are switched off.

(See paragraph 7.2)

Summary of Contents for 3000545

Page 1: ...CTA s a u Autov a A 2 Km 585 1 Abrera 08630 Barcelona Espa a Tel 34 937 700 877 Fax 34 937 702 362 e mail selecta jpselecta es website http www jpselecta es ULTRATERMOSTATO DE INMERSI N IMMERSION ULTR...

Page 2: ...a temperatura 7 7 2 Pantalla de AJUSTES 8 7 3 Pantalla de programaci n 8 7 4 Seleccionar un programa para ejecutarlo desde la pantalla de Trabajo 9 7 5 Pantalla de Trabajo 9 7 6 Bomba de circulaci n 9...

Page 3: ...display 0 1 C 0 1 C Funcionamiento temporizado Horas minutos Horas minutos Caudal bomba 10L min 10L min Mueble en acero pintado epoxy en acero inox con asas de transporte laterales 1 Informaci n gener...

Page 4: ...peratura 4 Informaci n sobre seguridad en la utilizaci n del equipo 4 4 Mantenimiento Antes de manipular en su interior desconecte el equipo de la toma de red La manipulaci n de los circuitos electr n...

Page 5: ...el ctrica Escoger una toma de corriente cercana al equipo y adecuada a la potencia del equipo Utilizar el cable de conexi n suministrado u otro de similares ca racter sticas Para su seguridad la toma...

Page 6: ...LA TRABAJO PROGRAMA 00 SAVE TIEMPO 00 00 TEMP 16 0 C OVERTMP 0 C UNDERTMP 0 C SETUP HH MM SS DD MM YY HH MM SS DD MM YY 22 9 C SET 35 2 FLOW 80 DURACI N SET H M 0 20 40 80 60 20 40 Anticong coche Car...

Page 7: ...H MM SS DD MM YY 22 9 C SET 40 0 FLOW 80 DURACI N SET H M 3Seleccionar la temperatura con las teclas su bir y bajar En el ejempo 40 C HH MM SS DD MM YY 22 9 C SET 40 0 FLOW 80 DURACI N SET H M HH MM S...

Page 8: ...ecuencia de toma de datos para el registro b Sensor externo Seleccione el valor Si si desea trabajar con una sonda externa conectada al conector de la parte posterior del equipo c Calibraci n OFFSET S...

Page 9: ...uraciones Circulaci n INTERNA El agua sale de la bomba por el tubo horizontal Ver fig 7 6 1 Con esta configuraci n se consigue una buena homogeneizaci n de la temperatura en el l quido de la cubeta Ci...

Page 10: ...el bajo de temperatura A 04 External RTD opened Sonda externa abierta A 05 External RTD shortcir cuited Sonda externa cruzada A 06 Internal RTD opened Sonda interna abierta A 07 Internal RTD shortcir...

Page 11: ...ONES CODIGO 80333 REV B 07 2020 Pag 11 J P SELECTA s a u Autov a A 2 Km 585 1 Abrera 08630 Barcelona Espa a Tel 34 937 700 877 Fax 34 937 702 362 e mail selecta jpselecta es website http www jpselecta...

Page 12: ...e any doubts or enquiries contact with J P SELECTA s technical service Do not use the equipment in explosive flammable or corrosive atmospheres 3 Technical Specification 3000545 3000554 Dimensions Hei...

Page 13: ...eat flammable or explosive materials or those which chemically react with violence Hazard risk Electric risk Risk of high temperature contact 4 Information about safety in the use of the equipment 4 4...

Page 14: ...he drain valve is closed 6 2 Connection to the mains Plug the equipment to a near socket suitable for the equipment power Use the connection cable supplied or a similar one For your safety the equipme...

Page 15: ...OPERATION SCREEN PROGRAM 00 SAVE TIME 00 00 TEMP 16 0 C OVERTMP 0 C UNDERTMP 0 C SETUP HH MM SS DD MM YY HH MM SS DD MM YY 22 9 C SET 35 2 FLOW 80 DURATION SET H M 0 20 40 80 60 20 40 Anticong coche C...

Page 16: ...s over HH MM SS DD MM YY 22 9 C SET 40 0 FLOW 80 DURATION SET H M 3Set the temperature with and 40 C on the picture HH MM SS DD MM YY 22 9 C SET 40 0 FLOW 80 DURATION SET H M HH MM SS DD MM YY 22 9 C...

Page 17: ...sensor Select the value YES if you want to work with an external probe connected to the connector on the back side of the equipment c Calibration OFFSET Use only this setting if you notice a deviation...

Page 18: ...circulation pump could operate in two configuration modes INTERNAL circulation Water or other will be pumped from horizontal pump output See fig 7 6 1 Use this configuration to make water circulation...

Page 19: ...rature level A 04 External RTD opened Open external probe A 05 External RTD shortcircuited Shortcircuited external probe A 06 Internal RTD opened Open internal probe A 07 Internal RTD shortcircuited S...

Page 20: ...ODE 80333 REV B 07 2020 Page 20 J P SELECTA s a u Autov a A 2 Km 585 1 Abrera 08630 Barcelona Espa a Tel 34 937 700 877 Fax 34 937 702 362 e mail selecta jpselecta es website http www jpselecta es J P...

Reviews: