DIP Switch
1. External button switch. ON - Three button switch; OFF - One button switch (X7 terminal CLS
button can be used to circularly control the main engine OPEN/STOP/CLOSE/STOP).
2. Automatic close time.
3. Automatic close time.
2 ON 3 OFF: automatic close time is 15s,
2 OFF 3 ON: automatic close time is 30s,
2 OFF 3 OFF: automatic close time is 45s,
2 ON 3 ON: no automatic close function.
Infrared connection
Infrared photocell function: In the closing process, when infrared ray of the infrared sensor is
covered, the gate will open immediately, to protect user and property security.
The distance between photocell receiver and photocell emitter should be not less than 2 meters,
otherwise will affect the induction of the photocell.
If connect the infrared photocell, please remove the short connection between I.R and GND on the
X5 terminal.
24VDC
24VDC
GND
GND
I.R
I.R
CLLM
CLLM
COM
COM
OPLM
OPLM
COM
COM
STP
STP
X5
X5
10A
10A 250V
250V
CLS
CLS
OPN
OPN
X1
X1
PE
PE N L
X8
X8
Com
Com Out
Out
Set
Set NC
NC
Infrared
Infrared receiver
receiver connecting
connecting
- +
- +
X7
X7
Infrared
Infrared emitter
emitter connecting
connecting
Figure 19