background image

7

8

Temperature Taking Hints

9

10

Vital Organs

Forehead Thermometer Advantages

Infrared Forehead Thermometer measures core body temperature, 
which is the temperature of a body's vital organs. (See Figure 1)  
This thermometer is designed to measure the temperature of the 
skin surface over the temporal artery, a major artery of the head.
The temporal artery is connected to the heart via the carotid artery,
directly leading from the aorta, the main trunk of the arterial system.
It offers constant blood flow. Therefore, body temperature changes
are reflected sooner in the forehead than they are in other parts of 
the body such as oral, rectal and underarm.

Figure 1

Real Time Clock Setting

Real Time Clock Setting

Real Time Clock Setting

Set the unit

Press  

 

Button

 to select the 

unit you want.

After the unit is set

,

press  

Button 

,the time format figure  will

 appear .

 

 

   

Test

Setting

  

③ 

Set the hour

Press and release the 

 Button 

to advance 

one hour until the correct hour appears.

After the hour is set, press 

 Button

, the Minute 

figure is flashing automatically.

   

Test

Setting

  

② 

Set the time format

The device can display the time in either 

an AM/PM (12-hour) or a 24:00

(24-hour) format. Press and release 

 button

  to select the format. 

With the preferred time format on the 

display, press 

 Button

,  the Hour 

figure is flashing automatically.

 

 

   

Test

Setting

    

When installing the battery, please set the parameters of the 
thermometer. With the thermometer off, press and hold 

Button 

to enter into setting mode.

Setting

④ 

Set the minute

Press and release the 

 Button 

to advance

one minute until the correct minute appears. 

After the minute is set, press 

 Button

, the Year 

figure is flashing automatically

.

   

Test

Setting

⑤ 

Set the year

Press and release the 

 Button  

to advance

one year until the correct year appears. 

After the year is set, press 

 Button

, the Month

figure will appear

.

 

Test

Setting

⑥ 

Set the month

Press and release the 

 Button 

 to advance 

one month until the correct month appears.

After the month is set, press 

 Button

, the Date

figure will appear.

Test

Setting

⑦ 

Set the date

Press and release the 

 Button

 to advance 

one day until the correct month appears.

After the day is set, press  

 Button ,

 Chinese

or English will appear. 

Test

Setting

 

    Set the language of voice

The device can set the language 

of voice in either Chinese or 

English. Press and release 

 BUTTON

  to select 

the language. With the preferred 

language on the display,

press 

 

BUTTON

 

setting mode.

 

   

Test

Setting

to exit the

Summary of Contents for DET-3018c

Page 1: ...08 Temperature Taking Hints 11 Illustration For Use 13 Memory Mode 18 Care And Cleaning 19 Battery Replacement 20 Specifications 21 Troubleshooting 22 Calibration 24 Symbol Explanation 25 Service 26 Warranty 27 Information Electromagnetic Compatibility Information 30 FCC 28 Document No Article No Version Date of Issue JDET 1804 011 004 2021 11 Z This appliance conforms to the following standards A...

Page 2: ...uetooth sign If the APP is successfully connected to the machine the Bluetooth sign will always be on otherwise it will keep flashing Real Time Clock Forehead Mode Object Mode Memory Mode There are 30 sets memories for forehead and object measurements Each memory also records the measurement date time mode icon Switch Please see the Real Time Clock Setting to learn how to change between Celsius an...

Page 3: ...ither an AM PM 12 hour or a 24 00 24 hour format Press and release button to select the format With the preferred time format on the display press Button the Hour figure is flashing automatically Test Setting When installing the battery please set the parameters of the thermometer With the thermometer off press and hold Button to enter into setting mode Setting Set the minute Press and release the...

Page 4: ...nt temperature for at least 10 minutes before taking a reading 3 Users should not drink eat or be physically active such as bathing showering shampooing and hair drying before while taking the measurement Remove hat and hair and wait 10 minutes before taking a reading 4 Oils or cosmetics on the forehead may give a lower temperature reading than the actual one Remove dirt from the forehead before t...

Page 5: ...ry life 2 Clean the probe after each use to ensure an accurate reading and avoid cross contamination See the section of Care and Cleaning for details 30 seconds BackLight In Forehead mode 1 The display will be lighted for 3 seconds when the unit is ready for measurement and the display will be lighted GREEN for 3 seconds when a measurement is completed with a reading less than 37 3 99 1 2 The disp...

Page 6: ...ttery when appears in the right corner upper of LCD display See Figure 7 2 Slide battery cover down as shown in Figure 8 3 Remove battery and install 2 new AAA alkaline batteries as shown in Figure 9 4 Slide battery cover back on Figure 7 Figure 8 Figure 9 Specifications Forehead mode 34 0 43 0 93 2 109 4 Object mode 0 100 32 212 Forehead mode 0 2 0 4 during 35 5 42 0 95 9 107 6 at 15 35 59 0 95 0...

Page 7: ...n Storage and Transportation 15 95 RH Humidity limitation The first num 2 Protected against solid foreign objects of 12 5 mm and greater The second num 2 Protection against vertically falling water drops when ENCLOSUREtilted up to 15 IP22 Troubleshooting In Forehead mode Temperature taken is higher than 43 0 109 4 In Object mode Temperature taken is higher than 100 212 Problem Solution The thermom...

Page 8: ...rient or relocate the receiving antenna Increase the distance between the equipment and the receiver Connect the equipment to an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Information Thermometer is warranted by manufacture to be free from defects in material and workmanship under normal use and s...

Page 9: ...d in the frequency range 80 MHz to 2 7 GHz are intended to decrease the likelihood that mobile portable communications equipment could cause interference if it is inadvertently brought into patient areas For this reason an additional factor of 10 3 has been incorporated into the formulae used in calculating the recommended separation distance for transmitters in these frequency ranges c Field stre...

Page 10: ...erify normal operation The use of accessories and power cord other than those specified with the exception of cables sold by the manufacturer of the equipment or system as replacement parts for internal components may result in increased emissions or decreased immunity of the equipment or system Electromagnetic Compatibility Information Electromagnetic Compatibility Information Electromagnetic Com...

Reviews: