Jøtul GF 100 DV II Nordic QT Installation And Operation Instructions Manual Download Page 31

31

3.

3.

3.

3.

3. Access the lower controls.

4

4

4

4

4..... Depress gas control knob slightly and turn clock-

wise              to “OFF”.  Do not force.

FOR YOUR SAFETY, READ BEFORE LIGHTING.

LIGHTING INSTRUCTIONS

TO TURN OFF GAS TO THE APPLIANCE:

LIGHTING INSTRUCTIONS

WARNING:

IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING

PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.

A.

A.

A.

A.

A. This appliance has a pilot which must be lit

by hand. When lighting the pilot, follow these
instructions exactly.

B

B

B

B

B..... B

B

B

B

BEF

EF

EF

EF

EFOR

OR

OR

OR

ORE LIGH

E LIGH

E LIGH

E LIGH

E LIGHT

TT

T

TIIIIING,

NG,

NG,

NG,

NG,     smell all around the

appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle to the floor.

W

W

W

W

WHA

HA

HA

HA

HAT 

T T

TT

T

TO DO I

O DO I

O DO I

O DO I

O DO IF 

F Y

Y

Y

Y

YOU S

OU S

OU S

OU S

OU SMELL G

MELL G

MELL G

MELL G

MELL GA

A

A

A

AS:

S:

S:

S:

S:

• Extinguish any open flame.
• Open windows.
• Do not light any appliance.
• Do not touch any electrical switches.
• Do not use any phone in your building.
• Immediately call your gas supplier from a

neighbor’s phone.

• If your gas supplier cannot be reached, call the

fire department.

C.

C.

C.

C.

C. Use only your hand to push in or turn the gas

control knob. Never use tools. If the knob will not
push in or turn by hand, do not try to repair it.
Call a qualified technician. Force or attempted
repair may result in a fire or explosion.

D

D

D

D

D..... Do not use this appliance if any part has been

under water. Immediately call a qualified service
technician to inspect the appliance and to
replace any part of the control system and any
gas control which has been under water.

1.

1.

1.

1.

1. STOP! Read the safety information above.

2.

2.

2.

2.

2. Access the lower controls.

3.

3.

3.

3.

3. Turn the stove ON/OFF switch to “OFF”, or set the

thermostat to lowest setting (if used).

4

4

4

4

4..... Confirm that the gas supply line shut-off valve is open.

5

55

55..... Push in gas control knob slightly and turn clockwise

to “OFF”.

NOTE: Knob cannot be turned from “PILOT” to “OFF”
unless the knob is pushed in slightly. Do not force.

6.

6.

6.

6.

6. Wait five (5) minutes to clear out any gas. If you then

smell gas, STOP! Follow “B” in the safety information
above on this page. If you do not smell gas, go to the
next step.

1.

1.

1.

1.

1. Turn ON/OFF switch to” OFF”. The pilot will remain lit for

normal service.

2.

2.

2.

2.

2. For complete shutdown, turn ON/OFF switch to “OFF”.

Pilot Assembly

77777.....  Push in gas control knob slightly and turn counter-

clockwise            to “PILOT”.

8.

8.

8.

8.

8. Push in control knob all the way and hold in.

Immediately light the pilot by triggering the spark
ignitor (push the red button repeatedly) until pilot
lights. Continue to hold the control knob in for
about one minute after
the pilot lights. Release
knob and it should
spring back. The pilot
should remain lit. If it
goes out, repeat Steps 5
through 8.

•  If knob does not
return when released,
stop and immediately call your service technician
or gas supplier.

•  If pilot will not stay lit after several tries, turn the
control knob to OFF and call your service techni-
cian or gas supplier.

9.

9.

9.

9.

9. Turn gas control knob counterclockwise           to “ON”.

10

10

10

10

10.....Turn the stove ON/OFF switch to “ON”, or set thermo-

stat (if used) to desired temperature.

Control Valve

Control

Knob

OFF

PILOT

ON

Summary of Contents for GF 100 DV II Nordic QT

Page 1: ...gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not us...

Page 2: ...2...

Page 3: ...ment 18 Air Shutter Adjustment 19 Wall Thermostat 20 Remote Control 20 Log Set Installation 20 System Check 21 Operation 22 Maintenance 22 Glass Replacement 22 Optional Blower 24 Illustrated Parts Bre...

Page 4: ...k Kit 155815 Fuel Conversion Kit NG 155629 Wall Thermostat 750003 Remote Control 129706 Mobile Home Floor Bracket Kit 154342 Universal Leg Leveler Kit 156096 The J tul GF 100 DV II Nordic QT is a Dire...

Page 5: ...J tul GF 200 DV II Nordic QT is a Direct Vent gas heater designed as a sealed combustion air circulat ing gas appliance for residential applications This appliance is approved for installation using...

Page 6: ...F ANY PART HAS BEEN UNDER WATER Call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which may have been under water Ne pas se se...

Page 7: ...ection must extend the full width and depth of the appliance It is not necessary to remove carpeting vinyl or linoleum from underneath the floor protection See fig 1 Safety Information Your stove will...

Page 8: ...4 in 603 mm Long Legs 27 in 686 mm J tul GF 100 DV II J tul GF 200 DV II Nordic QT Lillehammer A A A A A 49 in 1245 mm 51 1 2 in 1308 mm B B B B B 47 1 2 in 1206 mm 50 in 1270 mm C C C C C 46 in 1168...

Page 9: ...M A SEAL BETWEEN THE INNER AND OUTER PIPES NEVER MODIFY ANY VENTING COMPONENT OR USE ANY DAMAGED VENTING PRODUCT THE GAS APPLIANCE AND VENT SYSTEM MUST BE VENTED DIRECTLY TO THE OUTSIDE OF THE BUILDIN...

Page 10: ...these conditions Use approved vent manufacturer s Wall Straps to support an offset pipe run at three feet intervals to avoid excessive stress on the offsets A firestop is required at every floor Fire...

Page 11: ...ngth of the chimney and connect to both the unit and the termination cap A METAL BLOCK OFF PLATE MUST BE CONSTRUCTED AND INSTALLED ABOVE THE UNIT PRIOR TO THE END OF THE INTAKE FLEX AND MUST COMPLETEL...

Page 12: ...illustrated in fig 7 Vent Termination Diagram The horizontal termination cap must maintain a 3 clearance to any overhead combustible projections 2 1 2 or less It must also maintain 12 clearance from p...

Page 13: ...m the rear shroud of the stove 2 Align the holes in the wall shield with the holes in the rear shroud 3 Secure the wall shield to the stove with the two 1 4 hex head screws See fig 16 Figure 14 Termin...

Page 14: ...s particularly where windy conditions pevail In accordance with CSA B149 1 Installation Codes In accordance with the current ANSI Z223 1 NFFPA 54 National Fuel Gas Code Note Local Codes and Regulation...

Page 15: ...N STRUCTION AND SAFETY STANDARD TITLE 24 CFR PART 3280 THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS THAT IS INDICATED ON THE STOVE S RATING PLATE A GAS CONVERSION KIT IS PROVIDED WITH THE NORDI...

Page 16: ...ew variable regulator tower being sure that the gasket is properly positioned and tighten screws securely 13 Install the identification labels to the stove so that they can be seen by any person that...

Page 17: ...ANSI Z223 1 NFPA 54 OR CAN B149 All codes require a gas shut off valve gas cock and union to be installed in the supply line and in the same room as the appliance This allows for the disconnection of...

Page 18: ...TECHNICIAN IN ACCORDANCE WITH THE MANUFACTURER S INSTRUCTIONS AND ALL CODES AND REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION THE INFORMATION LABEL MUST BE FILLED OUT BY THE INSTALLER AND APPLIED...

Page 19: ...ttom of the firebox directly behind the gas valve See fig 26 2 Push the stem back to decrease air or pull it forward to increase air Make adjustments in small increments 1 8 and allow the burner to se...

Page 20: ...ove Follow the operating instructions included with the Remote Control unit CAUTION LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING THE CONTROLS WIRING ERRORS CAN CAUSE IMPROPER OR DANGEROUS OPE...

Page 21: ...uld project out of the pilot hood 1 at all three ports See figs 30 3 BURNER ADJUSTMENT This stove is equipped with a variable gas control valve that allows easy adjust ment of the flame height appeara...

Page 22: ...ABRASIVE SOLUTIONS These can cause stains Coffee tea and fruit juices will also stain Avoid contact with metal objects Trivets kettles or pots can damage the enamel Operation Familiarize yourself wit...

Page 23: ...asket to expose the adhesive 4 Apply the gasket to the panel wrapping the adhe sive side down around the panel edge See fig 34 5 Insert the gasketed glass panel into the frame and press the retainer c...

Page 24: ...ENT ANSI NFPA 70 NATIONAL ELECTRICAL CODE OR CSA C22 1 CANADIAN ELECTRICAL CODE THIS UNIT IS SUPPLIED WITH A THREE PRONG GROUNDING PLUG FOR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECT...

Page 25: ...ER AND DANGEROUS OPERATION VERIFY OPERATION AFTER SERVICING ATTENTION AU MOMENT DE L ENTRENTIEN DES COMMANDES ETIQUIETEZTOUS LE FILS AVANT LE DEBRANCHEMENT ES ERREURS DE CEBLAGE PEUVENT ENTRATUN FONCT...

Page 26: ...down Firebox Assembly Figure 39 A 1 2 3 4 4 4 4 4 4 5 6 7 8 10 11 12 13 33 24 28 27 25 26 24 29 30 31 20 21 22 17 16 15 14 23 19 22 22 18 63 47a 48 49 50 51 52 53 4 54 55 56 57 39 60 61 40 59 41 42 43...

Page 27: ...s Frame Matte Black 22136592 Glass Frame J tul Iron 22136585 Glass Replacement Kit 155599 Parts List GF 100 DV II GF 200 DV II Firebox Assembly ALWAYS USE REPLACEMENTS PARTS PROVIDED BY AN AUTHORIZED...

Page 28: ...28 J tul GF 200 DV II Lillehammer Illustrated Parts Breakdown Cast Iron and Associated Hardware J tul GF 100 DV II Nordic QT 2 7 8 6 5 9 4 3 1 12 11 10 10 10 2 10 Figure 41 Figure 40 1 3 4 2 2 4...

Page 29: ...195247 10195248 6 Left Door 10425592 10425527 10425529 10425536 10425585 10425546 10425547 10425548 7 Right Door 10425692 10425627 10425629 10425636 10425685 10425646 10425547 10425548 Front Assembly...

Page 30: ...and forward so that no gaps are evident at the panel joints as in Fig 44 8 Install the other Side Panel while holding the Upper Panel in position Adjust the panels so that the mortar joints align with...

Page 31: ...water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 1 1 1 1 1 STOP Read thesafet...

Page 32: ...he installation it is important that the these instructions be carefully read and understood J tul maintains a policy of continual product development Consequently products may differ in specification...

Reviews: