25
Blower Operation
The variable-speed blower will enhance heat circulation
around the firebox and out into the room. The blower is
controlled by a heat activated switch (snapstat) that will
function only when the control switch is in the AUTO
setting. After the fire has been burning for a time, the
snapstat will react to the heat and activate the blower.
Fan speed may be manually adjusted with the rheostat
knob. If the burner turns off, the blower will be shut off
automatically when the stove cools down.
If automatic blower circulation is not desired, place
the blower control switch in the MANUAL position. That
will override the snapstat allowing the blower to run
continuously.
M6 x 20 mm
Hex Bolts
Figure 38. Blower Wiring Diagram
CAUTION:
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN
SERVICING CONTROLS. WIRING ERRORS CAN CAUSE
IMPROPER AND DANGEROUS OPERATION.
VERIFY OPERATION AFTER SERVICING.
ATTENTION:
AU MOMENT DE L’ENTRENTIEN DES COMMANDES,
ETIQUIETEZ TOUS LE FILS AVANT LE DEBRANCHEMENT. ES
ERREURS DE CEBLAGE PEUVENT ENTRA TUN FONCTIONNE-
MENT INADEQUAT ET DANGEREUX.
4. Attach the Blower to the stove.
GF 100 DV II:
First install the Mounting Bracket to
the holes in the bottom of the rear shroud using two
#8 x 1/2” sheet metal screws. Then attach the Blower
to the Mounting Bracket using the two M6 flange
head hex bolts as shown in fig. 35 and 37.
GF 200 DV II:
Attach the Blower directly to the
tapped hole in the cast iron stove bottom using the
two M6 flange head hex bolts.
5. Attach either Snapstat wire connector to either
Snapstat terminal. See figs.35 and 37.
6. Connect power cord to the nearest outlet.
Snapstat
Connectors
Mounting Bracket
for GF100 DV II
#8 x 1/2” sheet
metal screws
Figure 37 . Attach Blower to
the stove bottom and
connect wires to Snapstat.
SNAPSTAT
BK
W
G
BLOWER
POWER
SUPPLY
W
RHEOSTAT
BK
BL
SWITCH
MANUAL OFF AUTO
GY
BK
W
G
BL
BK
AUTO OFF MANUAL