31
ENGLISH
Table of contents
1.0 Relationship to the authorities ............... 31
2.0 Technical data for the burn chamber ...... 31
3.0 Safety
..................................................... 34
4.0 Prior to Installation ................................ 35
5.0 Installation
.............................................. 35
6.0 Installation
completed
............................ 35
7.0 Optional
Extras
....................................... 36
8.0 Recycling
................................................ 36
Installation
drawings
............................... 56
On all our products there is a label
indicating the serial number and
year. Write this number in the
place indicated in the installation
instructions.
Always quote this serial number
when contacting your retailer or
Jøtul.
les combustibles recommandés.
Respectez les consignes d'utilisation. Utilisez uniquement
Verwenden Sie nur empfohlenen Brennstoffen.
Montage- und Bedienungsanleitung beachten.
Follow user`s instructions. Use only recommended fuels.
standard
Certificate/
The appliance can be used in a shared flue.
Minimum distance to adjacent combustible materials:
Emission of CO in combustion products
Serial no: Y-xxxx, Year: 200x
Manufacturer:
N-1602 Fredrikstad
Norway
Jøtul AS
POB 1441
Sweden
EUR
Intermittent
Nominal heat output
Norway
Country
Operational type
Fuel type
Operation range
Efficiency
Klasse II
Classification
Standard
Flue gas temperature
Room heater fired by solid fuel
Product:
Jøtul
SP Sveriges Provnings- och
221546
Forskningsinstitut AB
SP Swedish National
Testing and Research
Institute
:
Approved by
:
:
:
:
:
:
:
Minimum distance to adjacent combustible materials:
OGC
SP
EN
Serial no.
1.0 Relationship with the
authorities
Jøtul FS 175 is a freestanding product made of soapstone
which uses Jøtul I 520 as a burn chamber. The product can
be positioned against infl ammable walls at the distances
described in
fi g.1a
.
The installation of a fi replace must be carried out in
compliance with national laws and regulations. All
local ordinances, including those that refer to national
and European standards, must be complied with when
products are installed.
Contact your local building authorities regarding restrictions
and installation requirements.
The installation can only be put into use after it has been
checked by a qualifi ed inspector.
The product has been tested and documented as a
freestanding stove in accordance with EN 13240.
2.0 Technical data for the
burn chamber
Materials: Cast
iron
Surface treatment:
Black paint
Type of fuel:
Wood
Max. log length:
50 cm
Smoke outlet:
Top/back outlet or 90o bend.
Flue pipe dimension:
Ø 150 mm.
Weight:
110 kg + 230 kg
Optional equipment:
Adapter for outside air
connection and Kit for Ø 80
outside air hose.
Product dimensions, distances
See
fi g. 1a
Technical data in accordance with EN 13229
Nominal heat output:
7 kW
Effi
ciency:
77%
CO emissions (13% O2):
0.07%
CO emissions (13% O2):
884 mg/Nm3
OGC emissions (13% O2):
60 mg/Nm3
Dust emissions (13% O2):
14 mg/Nm3
Flue gas temperature:
305°C
Flue gas fl ow rate:
7.1 g/s
Chimney draft, EN 13229:
12 Pa
Recommended draft with smoke outlet: 16-18 Pa
Fuel consumption:
2.3 kg/h
Kindling quantity; nominal
1.7 kg
Max. kindling:
3.4 kg each time and
3.8
kg/h
Particulate emission in accordance
with NS 3059:
1.88 g/kg dry wood
Operation:
Intermittent
Intermittent operation means normal use of a fi replace.
This means that to refuel the fi re, you add more wood as
soon as the previous load of wood has burned down to
embers.
Summary of Contents for FS 175- I 520
Page 6: ...6...
Page 59: ...59 Fig 16 Fig 17 Fig 18 Fig 19...
Page 61: ...61 Fig 21 Fig 22...
Page 62: ...62...
Page 63: ...63...
Page 64: ...64...
Page 65: ...65...