Effective January 1, 2012

4)  Damage due to, or repair of, rust. Use of stove-top steamers may 

cause rust.

5)  Damage due to service performed by  an installer  or service agency, 

unless otherwise agreed to in writing by JØTUL. 

6)  Damage caused by unauthorized modification, use or repair.
7)  Costs incurred by travel time and/or loss of service.
8)  Labor or other costs associated with the repair of components 

beyond the warranty period.

9)  Damage incurred while the Jøtul Stove or Fireplace Insert is in transit.
IN NO EVENT SHALL JØTUL, ITS PARENT COMPANY, SHAREHOLDERS, 

AFFILIATES, OFFICERS, EMPLOYEES, AGENTS OR REPRESENTATIVES 

BE LIABLE OR RESPONSIBLE TO YOU FOR ANY SPECIAL, INDIRECT, 

INCIDENTAL, CONSEQUENTIAL, PUNITIVE OR OTHER SIMILAR DAMAGES, 

INCLUDING, BUT NOT LIMITED TO, LOST PROFITS, LOST SALES, INJURY 

TO PERSON OR PROPERTY, OR DAMAGES TO A STRUCTURE OR ITS 

CONTENTS, ARISING UNDER ANY THEORY OF LAW WHATSOEVER.  

ALL IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTIES 

OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, 

OR OTHERWISE, ARE LIMITED IN DURATION TO THE LENGTH OF THIS 

WRITTEN WARRANTY.  EXCEPT AS EXPRESSLY SET FORTH HEREIN, JØTUL 

MAKES NO ORAL, WRITTEN OR OTHER WARRANTY WITH RESPECT TO 

JØTUL OR SCAN STOVES OR FIREPLACES.

Some states do not allow the exclusion or limitation of incidental 

or consequential damages, or limitations on the length of implied 

warranties.  Therefore, the above exclusions or limitations may not 

apply to you.  This warranty gives you specific legal rights, and you may 

have other rights, which vary from state to state. 
JØTUL reserves the right to discontinue, modify or change the materials 

used to produce the Jøtul Stove or Fireplace.  JØTUL shall have the 

right to replace any defective component with substitute components 

determined by JØTUL to be of substantially equal quality and price. 
The dollar value of JØTULs liability for breach of this warranty shall be 

limited exclusively to the cost of furnishing a replacement component.  

JØTUL shall not in any event be liable for the cost of labor expended 

by others in connection with any defective component.  Any costs or 

expenses beyond those expressly assumed by JØTUL under the terms 

of this warranty shall be the sole responsibility of the owner(s) of the 

Jøtul Stove or Fireplace Insert.
No dealer, distributor, or other person is authorized to modify, augment, 

or extend this limited warranty on behalf of JØTUL.  NO MODIFICATION 

OR CHANGE TO THIS WARRANTY WILL BE EFFECTIVE UNLESS IT IS MADE 

IN A WRITTEN DOCUMENT MANUALLY SIGNED BY AN AUTHORIZED 

OFFICER OF JØTUL.
An authorized installer may have been provided with certain 

information related particularly to the Jøtul Stove or Fireplace Insert; 

however, no authorized installer or other person who may service the 

appliance is an agent of JØTUL.  No inference should be made that 

JØTUL has tested, certified, or otherwise pronounced any person as 

qualified to install or service the appliance.  JØTUL shall not be liable or 

otherwise responsible for any error or omission by a person installing 

or servicing a Jøtul Stove or Fireplace Insert.
If you believe your Jøtul or Fireplace Insert is defective, you should 

contact your nearest authorized Jøtul dealer, who will process a 

warranty claim.  IN ORDER TO QUALIFY FOR WARRANTY COVERAGE, 

JØTUL MUST RECEIVE NOTICE OF A POSSIBLE DEFECT WITHIN SIXTY (60) 

DAYS OF THE DATE THE DEFECT IS FIRST DISCOVERED, OR REASONABLY 

COULD HAVE BEEN DISCOVERED.
This warranty is given by Jøtul North America, Inc.,  

55 Hutcherson Drive, Gorham, Maine 04038 USA 

This warranty policy applies to wood-burning products identified by 

Jøtul trade names, as set forth below.

A. Limited Lifetime Warranty - Parts Only: 

Jøtul North America Inc. (JØTUL) warrants, to the original retail 

purchaser, that those baffle and air manifold components of the Jøtul 

Stove or Fireplace Insert specified above will be free of defects in 

material and workmanship for the life of the stove. This warranty is 

subject to the terms, exclusions and limitations set forth below.

 

B. Cast Iron, Enamel, and Steel Components:

Jøtul North America Inc. (JØTUL) warrants, to the original retail purchas-

er, that those components of the Jøtul Stove or Fireplace Insert specified 

above will be free of defects in material and workmanship for a period of 

five (5) years from the date of purchase.  This warranty is subject to the 

terms, exclusions and limitations set forth in the following text.

C.  Electrical Components (blowers, thermostatic switches): 

JØTUL warrants, to the original retail purchaser, that those components 

of the Jøtul Stove or Fireplace Insert specified above will be free of de-

fects in material and workmanship for a period of one (1) year from the 

date of purchase.  This warranty is subject to the terms, exclusions, and 

limitations set forth in the following text

JØTUL will repair or replace at its option, any of the above components 

determined by JØTUL to be covered by this warranty. You must, at your 

own expense, arrange to deliver or ship the component to an authorized 

Jøtul dealer and arrange for pickup or delivery of the component after 

repairs have been made.  If, upon inspection, JØTUL determines that 

the component is covered by this warranty, the repair or replacement 

will be made as set forth above. This warranty is not transferable and 

is extended only to, and is solely for the benefit of, the original retail 

purchaser of the Jøtul Stove or Fireplace Insert. This paragraph sets forth 

the sole remedy available under this warranty in the event of any defect 

in the Jøtul Stove or Fireplace Insert.

The warranty period for any replaced component will be the remaining 

unexpired portion of the warranty period for the original component.

Please retain your dated sales receipt in your records as proof of purchase. 

EXCLUSIONS AND LIMITATIONS

NOTICE: This warranty is void if installation or service is performed 

by someone other than an authorized installer or service agency, or if 

installation is not in conformance with the installation and operating 

instructions contained in this owners manual or local and/or national 

fire and building regulations.  A listing of local authorized installers, 

service agencies and gas suppliers can be obtained from the National 

Fireplace Institute at http://www.nficertified.org/.  
This warranty does not cover the following:
1)  Repair or replacement of parts that are subject to normal wear and 

tear during the warranty period or to parts that may require replace-

ment in connection with normal maintenance. These parts include 

paint, gaskets, burn plates, firebricks, fire grates, ceramic insulation 

blankets or glass (glass is only warranted against thermal breakage).

2)  Damage due to incorrect installations not in conformance with the 

installation instructions contained in this owners manual or local 

and/or national fire and building regulations. 

3)  Damage, including damage to enamel surfaces, caused by improper 

operation, over-firing, and/or misuse. Improper operation, such as 

burning the stove with the ash door open, can damage the stove. 

Over-firing occurs when any part of the stove glows red.  Over-firing 

can also be identified by warped plates, rust-colored cast iron, paint 

pigment that has turned dusty white, or bubbling, cracking and 

discoloration of the enamel finish.   Misuse includes, without limita-

tion, use that is not in conformance with the operating instructions 

contained in this owners manual.

Summary of Contents for F50 TL Rangeley

Page 1: ...Jøtul F 50 TL Rangeley Jøtul F 50 TL Rangeley Wood Stove Keep these instructions for future reference Installation and Operating Instructions for USA and Canada ...

Page 2: ...k Screen 157232 Enjoy the warmth of open door fire viewing with use of this custom fit spark screen Stove Top Thermometer 5002 We recommend the use of a magnetic stove top ther mometer to monitor the surface temperature of the stove The optimum surface temperature range for the most efficient performance is between 4000 F 7000 F 2050 C 3160 C Outside Air Kit 157320 This kit includes a plenum assem...

Page 3: ...use your new Jøtul F 50 TL wood stove Save these instructions and make them available to anyone using or servicing the stove Check Building Codes When installing operating and maintaining your Jøtul F 50 TL woodstove follow the guidelines presented in these instructions and make them available to anyone using or servicing the stove Your city town county or province may require a building permit to...

Page 4: ... accidental contact by small children Install smoke detectors in the living areas and bedrooms of your home Test them regularly and install new batteries twice annually When installed in the same room as the stove a smoke detector should be located as far from the stove as possible to prevent it from sounding when adding fuel to the fire Avoid creating a low pressure condition in the room where th...

Page 5: ... in the U S or in Canada CAN CSA B365 M and local codes 1 1 Unpack the Stove Inspect the stove for damage Contact your dealer immediately if any damage is found Do not install the stove if any damage is evident Contact your dealer Contents Top Load Door Tool BaffleHandleAssembly Bottom Heat Shield Flue Collar Heat Shield Stove Gloves 8 x 12 sheet metal screws 4 for Flue Collar Heat Shield M6 hex n...

Page 6: ... from the stove bottom Remove the four pre installed M6 flange head hex nuts and use them to attach the shield See fig 4 1 5 Chimney Connector Use 6 single wall or listed 6 double wall stovepipe to connect the stove to the chimney Single wall stovepipe must be black steel or stainless steel and have a minimum thickness of 24 gauge Do not use aluminum or galvanized steel pipe for chimney connection...

Page 7: ...in the temperatures necessary to maintain draft strength In extremely cold climates it may be necessary to reline the chimney or extend the height to help establish draft A tall interior masonry chimney is easier to keep warm and will perform the best under a variety of weather and environmental conditions The following guidelines give the necessary chimney requirements based on the national code ...

Page 8: ...nd at least 2 feet 61 cm higher than the highest part of the roof or structure that is within 10 feet 3 05 m of the chimney measured horizontally Chimneys shorter than 14 feet 4 27 m may not provide adequate draft Inadequate draft can result in smoke spillage when loading the stove or when the door is open Poor draft can also cause back puffing ignition of gas build up inside the firebox and slugg...

Page 9: ...d requires the removal of all combustible materials from at least 18 45 7 cm around the chimney connector s proposed location A 6 round liner requires a minimum opening 43 x 43 109 2 x 109 2 square Locate the pass through at least 18 from combustible ceiling materials The space that is cleared of combustible materials must remain empty Sheet metal panels can be used to cover the area However when ...

Page 10: ...alled without use of special tools or instructions 4 A spark arrester must be installed at the termination The net free area of the arrester above the chimney outlet must not be less than four times the net area of the chimney outlet and the vertical height of the arrester must not be less than one half the diameter of the chimney flue Openings shall not permit the passage of a sphere having a dia...

Page 11: ...those that are visible and also include materials that are behind noncombustible materials If you are not sure of the combustible nature of a material consult your local fire officials Remember Fire Resistant materials are considered combustible they are difficult to ignite but will burn Also Fire rated sheet rock is also considered combustible Contact your local building officials about restricti...

Page 12: ... 13 Alcove with Unprotected Walls Figure 14 Alcove with Wall Protection Figure 15 Hearthmount Clearances 4 4 Alcove Installation The Jøtul F 50 TL can be installed in an alcove as diagrammed in figs 13 14 1 The stove must be installed only with double wall chim ney connector 2 Wall and ceiling protection if used must extend over the entire area 3 Alcove floor protection must consist of a UL ULC or...

Page 13: ...w Flue Collar Heat Shield G 16 406mm H 10 254 mm I 11 280 mm J 8 203 mm K 5 127 mm L 6 153 mm Double Wall Connector M 14 356 mm N 9 229 mm O 12 305 mm P 6 152 mm Q 8 203 mm R 6 152 mm Double Wall Connector w Flue Collar Heat Shield S 14 356 mm T 6 152 mm U 12 305 mm V 5 127 mm W 6 152 mm X 3 5 89 mm Alcove w Double Wall Connector A 16 406 mm B 19 483 mm N A D 6 152 mm E 8 203 mm N A Figure 16 Clea...

Page 14: ...also determines the effectiveness of the air wash over the glass the higher the setting the cleaner the glass Additional air is separately directed into the top of the fire chamber to support combustion of exhaust gasses before passing out of the stove This unregulated Secondary Air enters through an inlet in the rear of the stove bottom and is heated as it passes through the rear of the stove int...

Page 15: ...ak in procedure for your stove Use a magnetic stove top thermometer to monitor stove temperature placed directly on the cook plate Set the Primary Air Shutter fully open all the way to the right 1 Light a small fire of newspaper and kindling at the front of the stove Gradually add small pieces of wood but only allow the stove to reach a maximum surface temperature of 200 F 93 C Continue burning at...

Page 16: ...are available to the stove when using the spark screen 5 7 Starting and Maintaining a Fire Burn only solid wood directly on the bottom grate of the stove Do not elevate the fire in any way WARNING DO NOT OPERATE THIS STOVE WITH THE ASH DOOR OPEN DOING SO MAY CAUSE DAMAGE AND WILL VOID YOUR WARRANTY We recommend use of a magnetic stovetop thermometer to monitor the surface temperature of the stove ...

Page 17: ...the fire Opening the door will only supply additional oxygen and intensify the fire When the fire in the flue has subsided resist the temptation to open the door to check on the fire The fire may have suffocated but could re ignite with a supply of fresh air After a chimney fire do not use the stove until the chimney connector and flue have been cleaned and inspected to ensure no damage has been s...

Page 18: ...ing the glass Never use the door to push wood into the firebox If the glass becomes cracked or broken follow the replacement procedure below Never operate the stove with a cracked or broken glass panel 6 0 Maintenance 6 1 Door Latch Adjustment Over time as the door gasket becomes compressed it may be necessary to adjust the door latch in order to maintain the integrity of the door seal To check th...

Page 19: ...e gasket clamp as shown in fig 20 Close and latch the door and then reopen Wipe away any excess cement that may have squeezed out from around the gasket 6 5 Glass Removal or Replacement See fig 20 1 Place the door face down on a protected surface 2 First just loosen each glass clip screw and then remove the clips 3 Lift the glass panel out of the door Use pliers and a putty knife to remove the old...

Page 20: ... Tools Required 10 mm wrench or socket driver pliers 1 4 socket driver or flat head screwdriver 4 mm hex key work gloves 2 Attach the Air Deflector See figs 21 and 22 3 Use pliers to bend the deflector tabs at the perforation lines as shown Attach the deflector to the interior side of the rear shroud using two 8 X 12 sheet metal screws from the exterior side 3 Attach the Blower Mounting Bracket Us...

Page 21: ...ts power source before cleaning or servicing Regular cleaning will help ensure you obtain maximum life from the blower Use a vacuum with a soft brush attachment to clean the blower fans and motor housing at least monthly or more frequently if there are pets in the home Keep the area under the stove free of dust and debris 8 Route the power cord to the nearest electrical outlet 9 10 1 2 3 5 6 7 4 4...

Page 22: ...ent Screen 4 Duct Clamps 2 The exterior air inlet should not be installed at a level higher than the stove bottom 1 Assembly will be easier with the Ash Door removed Release the cotter pin to remove the hinge pin 2 Attach the Duct Collar to the Main Manifold using four 8 x 12 mm sheet metal screws 3 Remove the four nuts from the studs protruding from the stove bottom Figure 26 Front Manifold place...

Page 23: ...e corners and secure each to the floor using an appropriate length lag screw 4 Orient the Front Manifold Panel as shown in figs 25 and 26 Set it in place above the ash housing between the front legs of the stove 5 Attach the Main Manifold to the four studs on the stove bottom and the two studs on the Front Manifold using the hex head nuts provided 6 Attach the Outside Air Bottom Heat Shield to the...

Page 24: ...24 139262 Rev_H 9 11 2012 Figure 29 F 50 TL Illustrated Parts ...

Page 25: ...atch 224733 52 Offset Latch Front Door Nickel Plated 157459 53 Front Door Tool Nickel Plate 157262 53a Receiver 224359 53b Wooden Handle 128064 53c M6 Rod 126835 53d Nut Housing 224358 8 0 Jøtul50TLRangeleyPartList No Description Part 58 Washer Hinge M6 12mm OD x 6mm ID x 0 5mm Zinc 117588 60 Gasket LD 250 Fiberglass Rope 200024 61 Glass Ceramic Door 50 TL 224158 62 Glass Clip w Gasket Top Steel S...

Page 26: ... to wood burning products identified by Jøtul trade names as set forth below A Limited Lifetime Warranty Parts Only Jøtul North America Inc JØTUL warrants to the original retail purchaser that those baffle and air manifold components of the Jøtul Stove or Fireplace Insert specified above will be free of defects in material and workmanship for the life of the stove This warranty is subject to the t...

Page 27: ...27 139262 Rev_H 9 11 2012 This page is intentionally blank ...

Page 28: ...038 USA Quality Jøtul AS utilizes quality controls conforming to NS EN ISO 9001 for product development manufacturing and distribution of stoves and fireplaces This policy is intended to provide you with the peace of mind that the Jøtul product you purchase meets or exceeds current uniform standards for quality and safety a continuation of the standards instituted at the company s inception in 185...