16
4.6 Adjusting the burn chamber
height for the Jøtul F
470
Series
Any unevenness between the burn chamber and the base/
pedestal/foot must be corrected.
This may also be done to reduce pressure on the draught valves
(prevents draught valves from becoming stiff).
Fig. 24
1. If the base has been mounted, the shelf and the inner plate
must be removed first.
2. Unscrew
the
screws
(A)
approx. 4 mm on both sides of the
product.
3. Unscrew
B
using an Allen key until you feel resistance in
the key. Then turn the adjustment screw to raise the burn
chamber as much as required.
4. Finally,
tighten
screws
A
.
5. Refit the base inner plate and shelf (only for base).
4.7 Securing the shelf plate in the base
Fig. 25
To ensure that the shelf in the base does not fall out, tilt the tip
(Fig. 25 A)
of the inner plate outwards.
ENGLISH
Summary of Contents for F 471
Page 117: ...117 ...
Page 118: ...118 ...