Prefabricated Chimneys
When connecting the Jøtul F
100
to a prefabricated
metal chimney always follow the pipe manufacturer’s
instructions and be sure to use the components that are
required. This usually includes a “smoke pipe adapter”
that is secured to the bottom section of the metal
chimney and allows the chimney pipe to be secured to
it with two sheet metal screws.
See figure 8
.
4.0 Clearance to Combustibles
Floor Protection
The Jøtul F
100
requires one of the following forms of
hearth protection:
1. Any UL, ULC or WH listed hearth board. (No bottom
heat shield required).
2. Any noncombustible material
with use of the bottom
heat shield.
All forms of protection must include a noncombustible
surface extending forward from the glass panel at least
16” for the U.S., or 18” (46cm) for Canada. Protection must
extend 8” (21 cm) from the sides and rear for both: the U.S.
and Canada.
This will result in a minimum floor protection of 37”
W x 38” D for the U.S. or 37” W x 40” D for Canada.
See
figure 9
.
In a rear vent installation, the floor protection must also
extend under the stove pipe a minimum of 2” (5 cm)
beyond either side of the pipe.
See figure 9
.
Figure 8. Prefabricated Listed Type HT Chimney.
Listed
Chimney
Ceiling
Support
to
Stove
Storm Collar
Listed Cap
Combustible
Ceiling Joists
Floor
Protector
Specified
clearance
Attic
Insulation
Shield
Flashing
Chimney
Connector
Figure 9. Hearth Protection.
A:
8” (21 cm)
B:
16” (US)
B:
46 cm (Can)
2”(5 cm)
37”U.S & CAN
B
A
A
A
38” (97 cm) U.S
40”(102 cm) CAN