background image

31

3.

Access the lower controls.

4.

Depress gas control knob slightly and turn clock-
wise              to “OFF”.  Do not force.

FOR YOUR SAFETY, READ BEFORE LIGHTING.

LIGHTING INSTRUCTIONS

TO TURN OFF GAS TO THE APPLIANCE:

LIGHTING INSTRUCTIONS

WARNING:

IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY

RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.

A.

This appliance has a pilot which must be lit
by hand. When lighting the pilot, follow
these instructions exactly.

B. BEFORE LIGHTING, 

smell all around the

appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle to the floor.

WHAT TO DO IF YOU SMELL GAS:

• Extinguish any open flame.
• Open windows.
• Do not light any appliance.
• Do not touch any electrical switches.
• Do not use any phone in your building.
• Immediately call your gas supplier from a

neighbor’s phone.

• If your gas supplier cannot be reached, call the

fire department.

C.

Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will
not push in or turn by hand, do not try to repair
it. Call a qualified technician. Force or attempted
repair may result in a fire or explosion.

D.

Do not use this appliance if any part has been
under water. Immediately call a qualified service
technician to inspect the appliance and to
replace any part of the control system and any
gas control which has been under water.

1.

STOP! Read the safety information above.

2.

Access the lower controls.

3.

Turn the stove ON/OFF switch to “OFF”, or set the
thermostat to lowest setting (if used).

4.

Confirm that the gas supply line shut-off valve is open.

5.

Push in gas control knob slightly and turn clockwise
to “OFF”.
NOTE: Knob cannot be turned from “PILOT” to “OFF”
unless the knob is pushed in slightly. Do not force.

6.

Wait five (5) minutes to clear out any gas. If you then
smell gas, STOP! Follow “B” in the safety information
above on this page. If you do not smell gas, go to the
next step.

1.

Turn ON/OFF switch to” OFF”. The pilot will remain lit for
normal service.

2.

For complete shutdown, turn ON/OFF switch to “OFF”.

Pilot Assembly

7.

 Push in gas control knob slightly and turn counter-
clockwise            to “PILOT”.

8.

Push in control knob all the way and hold in.
Immediately light the pilot by triggering the spark
ignitor (push the red button repeatedly) until pilot
lights. Continue to hold the control knob in for
about one minute after
the pilot lights. Release
knob and it should
spring back. The pilot
should remain lit. If it
goes out, repeat Steps 5
through 8.
•  If knob does not
return when released,
stop and immediately call your service technician
or gas supplier.
•  If pilot will not stay lit after several tries, turn
the control knob to OFF and call your service
technician or gas supplier.

9.

Turn gas control knob counterclockwise           to “ON”.

10.

Turn the stove ON/OFF switch to “ON”, or set

thermostat (if used) to desired temperature.

Control Valve

Control

Knob

OFF

PILOT

ON

Summary of Contents for Direct Vent Gas Fireplace GZ550s

Page 1: ...YOUR GAS SUPPLIER S INSTRUCTIONS IF YOU CANNOT REACH YOUR GAS SUPPLIER CALL THE FIRE DEPARTMENT AVERTISSEMENT ASSUREZ VOUS DE BIEN SUIVRE LES IN STRUCTIONS DANS CETTE NOTICE POUR REDUIRE AU MINIMUM LE...

Page 2: ...l stoves and fireplaces continuously since 1853 The J tul GZ550 DV Acadia fireplace combines advanced gas technology with the warm traditional elements of cast iron With proper care and use your firep...

Page 3: ...ighting Instructions Back Cover Unpacking the Fireplace 1 Before you remove the carton remove the cast iron parts that are packed around the fireplace cabinet PLEASE READ THESE INSTRUCTIONS IN THEIR E...

Page 4: ...1 CSA P 4 01 2 for Canada DO NOT ATTEMPT TO ALTER OR MODIFY THE CON STRUCTION OF THE APPLIANCE OR ITS COMPONENTS ANY MODIFICATION OR ALTERATION WILL VOID THE WARRANTY CERTIFICATION AND LISTING OF THIS...

Page 5: ...ou en l absence de tels reglements selon THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED SERVICE AGENCY DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THIS APPLIANCE OR ITS COMPONE...

Page 6: ...autres liquides a vapeur inflammables loin de l appareil Clothing or other flammable materials should not be placed ON or NEAR the Acadia gas fireplace Never allow any to use the fireplace if they ar...

Page 7: ...n DuraVent and Amerivent A 25 3 4 660 mm 5 8Vent Adaptor A 6 Vent Section Header Standoff Height 36 1 2 Figure 1 Cabinet Dimensions Figure 5 Corner framing dimensions 281 2 730mm 16 410mm 41 1041 mm 9...

Page 8: ...w of ventilation air around the fireplace Figure 8 Minimum Side Wall and Trim Clearance Measured from the cabinet not standoffs or cast iron panels Figure 6 Header and Side Standoffs Standoffs Header...

Page 9: ...APPLIANCE ANDVENT SYSTEM MUST BE VENTED DIRECTLYTOTHE OUTSIDE OFTHE BUILDING DO NOT CONNECTVENTTO A CHIMNEY SERVING A SOLID FUEL OR ANOTHER GAS APPLIANCE Joint Sealing Requirement Apply a 1 8 bead of...

Page 10: ...or offset vertical termination using 5 8 or 4 6 pipe Vertical Termination The vent must terminate within the shaded area designated on the graphs in Figs 12 and 13 Maximum Elbows Two 90 or Two 45 Do n...

Page 11: ...nce to outside corner Min 9 inches U S 12 inches 30 cm CAN We strongly recommend 12 inches particularly where windy conditions pevail G Clearance to inside corner Min 6 inches U S 12 inches 30 cm CAN...

Page 12: ...ly plug is included for protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THE PLUG Blower Fun...

Page 13: ...d secure it to the Vent Collar using 3 10 sheet metal screws 4 Confirm that the cabinet is positioned to align its forward edge with the finished surface of the wall facing The stud braces allow appro...

Page 14: ...vice For those locales where flexible gas lines are not permitted use the 3 8 iron fitting to make the connection at the left side of the Control Valve See Figures 25 and 26 Secure all joints tightly...

Page 15: ...altitudes use J tul High Altitude Kit 137403 In the U S THE DERATING KIT MUST BE INSTALLED BY AN AUTHORIZED SERVICE TECHNICIAN IN ACCOR DANCE WITH THE MANUFACTURER S INSTRUCTIONS AND ALL CODES AND RE...

Page 16: ...30 for Propane Tighten new orifice into the base of the pilot assembly Fuel Conversion The GZ550 DV Acadia Fireplace is designed to for use with either Natural gas or Propane It is shipped from the f...

Page 17: ...replace Apply LABEL B to the Rating Plate in the space provided 9 Reassemble the fireplace apply gas to the system and check for gas leaks including all gas lines before and after the valve NEVER USE...

Page 18: ...it Figure 33 ZG550 DV Acadia Blower Wiring Diagram Remote Control The optional J tul Remote Control can be installed on the Acadia gas fireplace Using the wire sup plied with the remote connect the re...

Page 19: ...e the bottom edge of each side panel between the Logset Base and the firebox wall and push the panel forward against the front lip of the firebox opening See Fig 37 4 Install the Lower Rear Panel Orie...

Page 20: ...ement There should not be a large gap between the two pieces as shown in Fig 42a 6 Position Log E to the rear of Log C Note that the cutout at in the lower end should be oriented to the left to clear...

Page 21: ...doors from the frame to lighten the assembly and ease installation They simply lift off of the hinges The door assembly attaches to the fireplace by engaging the three slots in the upper frame with t...

Page 22: ...s valve provides easy adjust ment of the flame height appearance and heat output To adjust the flame between the HI and LO setting rotate the HI LO knob located in the center of the valve face Flame h...

Page 23: ...ighten the locknut 3 Reassemble the fireplace including glass assem bly Allow the fireplace to burn 15 20 minutes on the HIGH setting observing the flame continu ously 4 If the flame appears weak slow...

Page 24: ...ate through the area 3 Condensation may develop on the glass upon each lighting of the appliance This fog will disappear as the glass heats 4 Keep the controls and the area under the appli ance free o...

Page 25: ...CLEANERS ON THE GLASS NEVER CLEAN THE GLASS WHEN IT IS HOT Gasket Inspection It is important that the glass gasket be inspected at least annually Examine the ribbon gasket for signs of deterioration...

Page 26: ...13 12 13 1 51 49 48 47 46 50 54 55 56 57 43 53 11 9 8 7 6 10 16 17 18 12 1 4 2 5 3 13 14 15 19 20 24 25 29 28 27 26 30 23 21 25 22 28 31 34 35 37 38 32 33 42 36 39 39 40 41 41 45 44 46 52 58 See Inset...

Page 27: ...69 29 Cabinet Wall Right 129753 30 Firebox 129733 32 Frame Hanger 129760 33 Relief Door 129759 34 Relief Door Guide 2 220004 35 Gasket Heat Exchanger 129673 36 Heat Exchanger 129736 37 Top Shroud Leve...

Page 28: ...____________________________________________ SERVICE LOG Third Year Name of Technician________________________ Company Name____________________________ Date of service_____________________________ Wo...

Page 29: ...29...

Page 30: ...30...

Page 31: ...ntrol system and any gas control which has been under water 1 STOP Read the safety information above 2 Access the lower controls 3 Turn the stove ON OFF switch to OFF or set the thermostat tolowestset...

Page 32: ...product development Consequently products may differ in specification color or type of accessories from those illustrated or described in various publications J tul vise sans cesse a ameliorer ses pr...