Flame Appearance / Air Shutter
Adjustment

THE ACADIA GAS FIREPLACE IS SHIPPED FROM THE
FACTORY EQUIPPED TO USE NATURAL GAS.  IF THE
BURNER HAS BEEN CONVERTED FOR USE WITH
PROPANE, IT WILL BE NECESSARY TO ADJUST THE AIR
SHUTTER ON THE BURNER TUBE TO ACHIEVE THE
PROPER GAS TO AIR MIX.  See Figure 26.

WARNING:

AIR SHUTTER ADJUSTMENTS SHOULD ONLY

BE PERFORMED BY A QUALIFIED PROFES-

SIONAL SERVICE TECHNICIAN.

The air shutter adjustment can also help achieve the
desired flame appearance.  Generally, flame appear-
ance is a matter of individual preference, however a
warm yellowish flame is most common. See Fig. 49.

Closing the air shutter

 -  will generate very long

yellow flames resulting in soot.  Sooting produces
black deposits on the logs, on the inside walls of
the appliance, and potentially on the exterior
termination cap.
Sooting is caused by incomplete combustion in
the flames and lack of combustion air entering
the air shutter opening.

Opening the air shutter 

- will generate a flame that is

blue and transparent, or an “anemic” flame.  This
flame is generally more efficient but not as pretty.

3.  BURNER ADJUSTMENT:

  Your Jøtul GZ550 Acadia

gas fireplace is equipped with a variable gas
control valve.  This valve provides easy adjust-
ment of the flame height appearance and heat
output.  To adjust the flame between the HI and
LO setting, rotate the HI/LO knob, located in the
center of the valve face.  Flame height will adjust
approximately 1.0” to 1.5” between the HI and LO
settings.

NO SMOKE OR SOOT SHOULD BE PRESENT.  CHECK
LOG PLACEMENT IF ANY SOOT OR SMOKE IS DE-
TECTED.  IF SOOT OR SMOKE PERSISTS, THE AIR
SHUTTER MAY NEED TO BE ADJUSTED.

CAUTION:

DO NOT ATTEMPT TO ALTER THE FLAME

APPEARANCE BY POSITIONING THE GAS

VALVE IN ANY OTHER POSITION OTHER

THAN THE FULL “ON” POSITION.

System Check

1.  PURGING THE GAS LINE: 

 When lighting the

appliance for the first time it will take a few
moments to clear the gas line of air.  Once this
purge is complete, the appliance will operate as
described in the lighting instructions located on
the fireplace’s rating plate and back cover of this
manual.

2.  PILOT FLAME: 

 The pilot flame should be steady,

not lifting or floating.  The flame should be blue
in color around the pilot hood

,

 with traces of

yellow toward the outer edges.  It is imperative
that the pilot flame engulf the top 3/8” of the
thermopile (power generator) and the top 1/8” of
the quick drop out thermocouple.  The pilot flame
should project out of the pilot hood 1” at all three
ports. See Figure 48.

(25mm)

3/8”

(8mm)

Min.

1/8”

(3mm)

Min.

Thermocouple

Ignitor

Thermopile

Pilot Hood

Figure 48   Correct Pilot Flame Pattern

Summary of Contents for Direct Vent Gas Fireplace GZ550s

Page 1: ...YOUR GAS SUPPLIER S INSTRUCTIONS IF YOU CANNOT REACH YOUR GAS SUPPLIER CALL THE FIRE DEPARTMENT AVERTISSEMENT ASSUREZ VOUS DE BIEN SUIVRE LES IN STRUCTIONS DANS CETTE NOTICE POUR REDUIRE AU MINIMUM LE...

Page 2: ...l stoves and fireplaces continuously since 1853 The J tul GZ550 DV Acadia fireplace combines advanced gas technology with the warm traditional elements of cast iron With proper care and use your firep...

Page 3: ...ighting Instructions Back Cover Unpacking the Fireplace 1 Before you remove the carton remove the cast iron parts that are packed around the fireplace cabinet PLEASE READ THESE INSTRUCTIONS IN THEIR E...

Page 4: ...1 CSA P 4 01 2 for Canada DO NOT ATTEMPT TO ALTER OR MODIFY THE CON STRUCTION OF THE APPLIANCE OR ITS COMPONENTS ANY MODIFICATION OR ALTERATION WILL VOID THE WARRANTY CERTIFICATION AND LISTING OF THIS...

Page 5: ...ou en l absence de tels reglements selon THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED SERVICE AGENCY DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THIS APPLIANCE OR ITS COMPONE...

Page 6: ...autres liquides a vapeur inflammables loin de l appareil Clothing or other flammable materials should not be placed ON or NEAR the Acadia gas fireplace Never allow any to use the fireplace if they ar...

Page 7: ...n DuraVent and Amerivent A 25 3 4 660 mm 5 8Vent Adaptor A 6 Vent Section Header Standoff Height 36 1 2 Figure 1 Cabinet Dimensions Figure 5 Corner framing dimensions 281 2 730mm 16 410mm 41 1041 mm 9...

Page 8: ...w of ventilation air around the fireplace Figure 8 Minimum Side Wall and Trim Clearance Measured from the cabinet not standoffs or cast iron panels Figure 6 Header and Side Standoffs Standoffs Header...

Page 9: ...APPLIANCE ANDVENT SYSTEM MUST BE VENTED DIRECTLYTOTHE OUTSIDE OFTHE BUILDING DO NOT CONNECTVENTTO A CHIMNEY SERVING A SOLID FUEL OR ANOTHER GAS APPLIANCE Joint Sealing Requirement Apply a 1 8 bead of...

Page 10: ...or offset vertical termination using 5 8 or 4 6 pipe Vertical Termination The vent must terminate within the shaded area designated on the graphs in Figs 12 and 13 Maximum Elbows Two 90 or Two 45 Do n...

Page 11: ...nce to outside corner Min 9 inches U S 12 inches 30 cm CAN We strongly recommend 12 inches particularly where windy conditions pevail G Clearance to inside corner Min 6 inches U S 12 inches 30 cm CAN...

Page 12: ...ly plug is included for protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THE PLUG Blower Fun...

Page 13: ...d secure it to the Vent Collar using 3 10 sheet metal screws 4 Confirm that the cabinet is positioned to align its forward edge with the finished surface of the wall facing The stud braces allow appro...

Page 14: ...vice For those locales where flexible gas lines are not permitted use the 3 8 iron fitting to make the connection at the left side of the Control Valve See Figures 25 and 26 Secure all joints tightly...

Page 15: ...altitudes use J tul High Altitude Kit 137403 In the U S THE DERATING KIT MUST BE INSTALLED BY AN AUTHORIZED SERVICE TECHNICIAN IN ACCOR DANCE WITH THE MANUFACTURER S INSTRUCTIONS AND ALL CODES AND RE...

Page 16: ...30 for Propane Tighten new orifice into the base of the pilot assembly Fuel Conversion The GZ550 DV Acadia Fireplace is designed to for use with either Natural gas or Propane It is shipped from the f...

Page 17: ...replace Apply LABEL B to the Rating Plate in the space provided 9 Reassemble the fireplace apply gas to the system and check for gas leaks including all gas lines before and after the valve NEVER USE...

Page 18: ...it Figure 33 ZG550 DV Acadia Blower Wiring Diagram Remote Control The optional J tul Remote Control can be installed on the Acadia gas fireplace Using the wire sup plied with the remote connect the re...

Page 19: ...e the bottom edge of each side panel between the Logset Base and the firebox wall and push the panel forward against the front lip of the firebox opening See Fig 37 4 Install the Lower Rear Panel Orie...

Page 20: ...ement There should not be a large gap between the two pieces as shown in Fig 42a 6 Position Log E to the rear of Log C Note that the cutout at in the lower end should be oriented to the left to clear...

Page 21: ...doors from the frame to lighten the assembly and ease installation They simply lift off of the hinges The door assembly attaches to the fireplace by engaging the three slots in the upper frame with t...

Page 22: ...s valve provides easy adjust ment of the flame height appearance and heat output To adjust the flame between the HI and LO setting rotate the HI LO knob located in the center of the valve face Flame h...

Page 23: ...ighten the locknut 3 Reassemble the fireplace including glass assem bly Allow the fireplace to burn 15 20 minutes on the HIGH setting observing the flame continu ously 4 If the flame appears weak slow...

Page 24: ...ate through the area 3 Condensation may develop on the glass upon each lighting of the appliance This fog will disappear as the glass heats 4 Keep the controls and the area under the appli ance free o...

Page 25: ...CLEANERS ON THE GLASS NEVER CLEAN THE GLASS WHEN IT IS HOT Gasket Inspection It is important that the glass gasket be inspected at least annually Examine the ribbon gasket for signs of deterioration...

Page 26: ...13 12 13 1 51 49 48 47 46 50 54 55 56 57 43 53 11 9 8 7 6 10 16 17 18 12 1 4 2 5 3 13 14 15 19 20 24 25 29 28 27 26 30 23 21 25 22 28 31 34 35 37 38 32 33 42 36 39 39 40 41 41 45 44 46 52 58 See Inset...

Page 27: ...69 29 Cabinet Wall Right 129753 30 Firebox 129733 32 Frame Hanger 129760 33 Relief Door 129759 34 Relief Door Guide 2 220004 35 Gasket Heat Exchanger 129673 36 Heat Exchanger 129736 37 Top Shroud Leve...

Page 28: ...____________________________________________ SERVICE LOG Third Year Name of Technician________________________ Company Name____________________________ Date of service_____________________________ Wo...

Page 29: ...29...

Page 30: ...30...

Page 31: ...ntrol system and any gas control which has been under water 1 STOP Read the safety information above 2 Access the lower controls 3 Turn the stove ON OFF switch to OFF or set the thermostat tolowestset...

Page 32: ...product development Consequently products may differ in specification color or type of accessories from those illustrated or described in various publications J tul vise sans cesse a ameliorer ses pr...

Reviews: