background image

19

Brick Panel Assembly

Install the optional Brick Panels before placing the
Logset. Place the panels in position in the order as
numbered in Fig. 32.  No fasteners or tools are
required.

Figure 35.   Panel installation order.

1. Remove the Glass Frame, if you have not already

done so.

 Open the lower control panel and locate

the two frame latches under the firebox floor. See
Fig. 36. Pull the latch handle forward to disengage
it from the bottom of the glass frame. You can
then pull the frame out and up off of the three
retainer tabs at the top of the firebox opening.
Set the Glass Frame out of the way.

2. Remove the Fettle and Logset.

 These parts are not

fastened. Simply lift them out of the firebox.

3. Install the Side Panels.

 Engage the bottom edge

of each side panel between the Logset Base and
the firebox wall and push the panel forward
against the front lip of the firebox opening. See
Fig. 37.

4. Install the Lower Rear Panel.

  Orient the panel so

that the beveled edge is on top and the mortar
joints align with those on the side panels. Engage
the bottom edge between the rear wall and the
base. Press the panel snugly between the two
side panels. See Fig.38.

5. Install the Upper Rear Panel.

 This will also be a

snug fit. Set the panel up high and then carefully
lower it to seat its lower edge against the top of
the other rear panel. The side panels will hold it in
place.

Left Side

Panel,

220032

Right Side
Panel,
220033

Lower Rear Panel,

220030

Upper Rear Panel,

220031

4

3

2

1

Figure 36.  Glass Frame latch locations.

Pull Frame Latches to

Release Frame

Figure 38. Install Lower Rear Panel.

Bevelled Edge

Figure 37. Install the Side Panels.

Side
Panel

Logset Base

Summary of Contents for Direct Vent Gas Fireplace GZ550s

Page 1: ...YOUR GAS SUPPLIER S INSTRUCTIONS IF YOU CANNOT REACH YOUR GAS SUPPLIER CALL THE FIRE DEPARTMENT AVERTISSEMENT ASSUREZ VOUS DE BIEN SUIVRE LES IN STRUCTIONS DANS CETTE NOTICE POUR REDUIRE AU MINIMUM LE...

Page 2: ...l stoves and fireplaces continuously since 1853 The J tul GZ550 DV Acadia fireplace combines advanced gas technology with the warm traditional elements of cast iron With proper care and use your firep...

Page 3: ...ighting Instructions Back Cover Unpacking the Fireplace 1 Before you remove the carton remove the cast iron parts that are packed around the fireplace cabinet PLEASE READ THESE INSTRUCTIONS IN THEIR E...

Page 4: ...1 CSA P 4 01 2 for Canada DO NOT ATTEMPT TO ALTER OR MODIFY THE CON STRUCTION OF THE APPLIANCE OR ITS COMPONENTS ANY MODIFICATION OR ALTERATION WILL VOID THE WARRANTY CERTIFICATION AND LISTING OF THIS...

Page 5: ...ou en l absence de tels reglements selon THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED SERVICE AGENCY DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THIS APPLIANCE OR ITS COMPONE...

Page 6: ...autres liquides a vapeur inflammables loin de l appareil Clothing or other flammable materials should not be placed ON or NEAR the Acadia gas fireplace Never allow any to use the fireplace if they ar...

Page 7: ...n DuraVent and Amerivent A 25 3 4 660 mm 5 8Vent Adaptor A 6 Vent Section Header Standoff Height 36 1 2 Figure 1 Cabinet Dimensions Figure 5 Corner framing dimensions 281 2 730mm 16 410mm 41 1041 mm 9...

Page 8: ...w of ventilation air around the fireplace Figure 8 Minimum Side Wall and Trim Clearance Measured from the cabinet not standoffs or cast iron panels Figure 6 Header and Side Standoffs Standoffs Header...

Page 9: ...APPLIANCE ANDVENT SYSTEM MUST BE VENTED DIRECTLYTOTHE OUTSIDE OFTHE BUILDING DO NOT CONNECTVENTTO A CHIMNEY SERVING A SOLID FUEL OR ANOTHER GAS APPLIANCE Joint Sealing Requirement Apply a 1 8 bead of...

Page 10: ...or offset vertical termination using 5 8 or 4 6 pipe Vertical Termination The vent must terminate within the shaded area designated on the graphs in Figs 12 and 13 Maximum Elbows Two 90 or Two 45 Do n...

Page 11: ...nce to outside corner Min 9 inches U S 12 inches 30 cm CAN We strongly recommend 12 inches particularly where windy conditions pevail G Clearance to inside corner Min 6 inches U S 12 inches 30 cm CAN...

Page 12: ...ly plug is included for protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THE PLUG Blower Fun...

Page 13: ...d secure it to the Vent Collar using 3 10 sheet metal screws 4 Confirm that the cabinet is positioned to align its forward edge with the finished surface of the wall facing The stud braces allow appro...

Page 14: ...vice For those locales where flexible gas lines are not permitted use the 3 8 iron fitting to make the connection at the left side of the Control Valve See Figures 25 and 26 Secure all joints tightly...

Page 15: ...altitudes use J tul High Altitude Kit 137403 In the U S THE DERATING KIT MUST BE INSTALLED BY AN AUTHORIZED SERVICE TECHNICIAN IN ACCOR DANCE WITH THE MANUFACTURER S INSTRUCTIONS AND ALL CODES AND RE...

Page 16: ...30 for Propane Tighten new orifice into the base of the pilot assembly Fuel Conversion The GZ550 DV Acadia Fireplace is designed to for use with either Natural gas or Propane It is shipped from the f...

Page 17: ...replace Apply LABEL B to the Rating Plate in the space provided 9 Reassemble the fireplace apply gas to the system and check for gas leaks including all gas lines before and after the valve NEVER USE...

Page 18: ...it Figure 33 ZG550 DV Acadia Blower Wiring Diagram Remote Control The optional J tul Remote Control can be installed on the Acadia gas fireplace Using the wire sup plied with the remote connect the re...

Page 19: ...e the bottom edge of each side panel between the Logset Base and the firebox wall and push the panel forward against the front lip of the firebox opening See Fig 37 4 Install the Lower Rear Panel Orie...

Page 20: ...ement There should not be a large gap between the two pieces as shown in Fig 42a 6 Position Log E to the rear of Log C Note that the cutout at in the lower end should be oriented to the left to clear...

Page 21: ...doors from the frame to lighten the assembly and ease installation They simply lift off of the hinges The door assembly attaches to the fireplace by engaging the three slots in the upper frame with t...

Page 22: ...s valve provides easy adjust ment of the flame height appearance and heat output To adjust the flame between the HI and LO setting rotate the HI LO knob located in the center of the valve face Flame h...

Page 23: ...ighten the locknut 3 Reassemble the fireplace including glass assem bly Allow the fireplace to burn 15 20 minutes on the HIGH setting observing the flame continu ously 4 If the flame appears weak slow...

Page 24: ...ate through the area 3 Condensation may develop on the glass upon each lighting of the appliance This fog will disappear as the glass heats 4 Keep the controls and the area under the appli ance free o...

Page 25: ...CLEANERS ON THE GLASS NEVER CLEAN THE GLASS WHEN IT IS HOT Gasket Inspection It is important that the glass gasket be inspected at least annually Examine the ribbon gasket for signs of deterioration...

Page 26: ...13 12 13 1 51 49 48 47 46 50 54 55 56 57 43 53 11 9 8 7 6 10 16 17 18 12 1 4 2 5 3 13 14 15 19 20 24 25 29 28 27 26 30 23 21 25 22 28 31 34 35 37 38 32 33 42 36 39 39 40 41 41 45 44 46 52 58 See Inset...

Page 27: ...69 29 Cabinet Wall Right 129753 30 Firebox 129733 32 Frame Hanger 129760 33 Relief Door 129759 34 Relief Door Guide 2 220004 35 Gasket Heat Exchanger 129673 36 Heat Exchanger 129736 37 Top Shroud Leve...

Page 28: ...____________________________________________ SERVICE LOG Third Year Name of Technician________________________ Company Name____________________________ Date of service_____________________________ Wo...

Page 29: ...29...

Page 30: ...30...

Page 31: ...ntrol system and any gas control which has been under water 1 STOP Read the safety information above 2 Access the lower controls 3 Turn the stove ON OFF switch to OFF or set the thermostat tolowestset...

Page 32: ...product development Consequently products may differ in specification color or type of accessories from those illustrated or described in various publications J tul vise sans cesse a ameliorer ses pr...

Reviews: