82695
_Op&Ins MAN_TR2600_K
5-1
5
OPERATION
The AIS BS includes a transponder to be used in a configuration with a Base Station Controller
(BSC)
Figure 5, TR-2600 AIS BS
5.1
Connecting power
After connecting the antennas and Inputs/Outputs, the DC power can be connected to the TR-2600
transponder through the AC/DC Power supply unit, PSU-7002 in the rack. This PSU transform
from 115-230V AC to 28 V DC. An optional DC input is provided in the PSU-7002 , if automatic
switchover to 24V DC is needed. The DC input voltage must be within 24VDC +30% / -10%. The
power consumption is 60W.
At startup, the TR-2600 will look for connected sensors and equipment for 20 –30 seconds. The
display will show:
After a while the alarm status will be indicated. Press [Del] key to reset the alarm settings.
Loading …
Please wait