82695
_Op&Ins MAN_TR2600_K 4-5
4.2.1
Cable installation
All outdoor installed connectors on coaxial cables should be fitted with preventive isolation such as
vulcanizing tape to protect against water penetration into the antenna cable.
Coaxial cables should be installed in separate signal cable channels/tubes and at least 10 cm away
from power supply cables. Crossing of cables should be done at right angles (90°). The minimum
bend radius of the coaxial cable should be 5 times the cable's outer diameter.
4.3
Transponder unit
The transponder unit is installed in a 19`` rack. When selecting a mounting location for the
transponder the following guidelines apply:
1.
Keep the transponder out of direct sunlight.
2.
The temperature and humidity should be moderate and stable.
3.
The mounting location should be well ventilated.
4.
Mount the unit where shock and vibration are minimal.
Keep the unit away from electromagnetic field generating equipment such as motor and
generator.
Leave sufficient space at the sides and rear of the unit for maintenance and repair. Do also
leave slack in cables for same reason.