7. Clean all the valve parts, body and shaft. 
 

           

 

 

 

8. Reassemble the inner parts and shaft.  
Screw the shaft assembly back on to the 
valve body (max. torque 7Nm) using a 13 
mm wrench. 

     

 

10. Swith on the electrical supply. 

 

9. Reposition the coil, timer and connector 
assembly on to the valve, replace the top nut 
and tighten the top nut (max. torque 1Nm) 
using a 14 mm wrench. 

 

 

11. Open the ball valve in front of the filter  to 
restore normal system pressure. 
 

 

12. Press the test button to check the valve 
function. 

 

             

 

     

 

13.Your TEC-11 is now ready for operation!

 

 

 

Summary of Contents for TEC-11

Page 1: ...e TEC 11 removes condensate automatically from compressed air filters and i e small dental compressors The TEC 11 is designed for ALL compressed air filters regardless of their capacity or size The TE...

Page 2: ...fe working practices and observe all regulations and legal requirements for safety when operating this product When handling operating or carrying out maintenance on this product personnel must employ...

Page 3: ...3 EXPLODED VIEW IDENTIFY ALL COMPONENTS DIAGRAM Top nut Coil Flat gasket TEC 11 timer Connector gasket Connector Screw Shaft Spring Plunger Body...

Page 4: ...ed out 3 The drain is shipped fully assembled Disassemble the drain before installation by unscrewing the screw in the connector and the top nut above the coil see page 3 for an exploded view 4 Locate...

Page 5: ...the gasket and the coil 7 Mount the timer on to the coil as illustrated below 8 Remove the protection cap from the connector and connect your power cable to the connector as shown below 9 Place the c...

Page 6: ...lve function 14 Adjust the OFF button to suit your system i e 20 min 13 The drain is now at full system pressure and will periodically discharge any condensate it receives from your compressed air sys...

Page 7: ...out 1 Close the condensate supply i e close the ball valve in front of the filter 2 Press the TEST button to empty the unit of any residual condensate and to depressurise the TEC 11 valve 3 Switch off...

Page 8: ...ing a 13 mm wrench 10 Swith on the electrical supply 9 Reposition the coil timer and connector assembly on to the valve replace the top nut and tighten the top nut max torque 1Nm using a 14 mm wrench...

Page 9: ...9 SERVICE CHART Date Description Name...

Page 10: ...on DIN 43650B ISO 6952 Indicators Yellow LED s indicating on off Valve type 2 2 Way direct acting valve Connections 1 8 or 1 4 BSP or NPT Max Pressure 0 16 BAR 21 bar optional Operating Temperature 2...