background image

 

 

 
SAFETY INSTRUCTIONS 

 
SAFETY AND PROPER USAGE 

To ensure safe and enduring performance of this product, you must comply strictly with the 
instructions enclosed herein. Non-compliance with instructions or improper handling of the 
product will void your warranty! This product is designed to drain condensate from compressed 
air systems. Usage of this product in conditions not specified in this manual or in contrary to the 
instructions hereby provided is considered IMPROPER. The manufacturer will not be held liable 
for any damages resulting from improper use of the product. 

 

 

 

SAFETY & WARNING INSTRUCTIONS 
 
ATTENTION 

- Observe valid and generally accepted safety rules when planning, installing and using this 
product. 
- Take proper measures to prevent unintentional operation of the product or damage to it. 
- Do not attempt to disassemble this product or lines in the system while they are under 
pressure. 
- Always depressurise the compressed air system before working on the system. 

 

It is important that personnel use safe working practices and observe all regulations and 
legal requirements for safety when operating this product. When handling, operating or 
carrying out maintenance on this product, personnel must employ safe engineering 
practices and observe all local health & safety requirements & regulations. International 
users refer to regulations that prevail within the country of installation. Most accidents, 
which occur during the operation and maintenance of machinery, are the result of failure 
to observe basic safety rules or precautions. An accident can often be avoided by 
recognising a situation that is potentially dangerous. Improper operation or maintenance 
of this product could be dangerous and result in an accident causing injury or death. The 
manufacturer cannot anticipate every possible circumstance, which may represent a 
potential hazard.   The 

WARNINGS 

in this manual cover the most common potential 

hazards and are therefore not all-inclusive. If the user employs an operating procedure, an 
item of equipment or a method of working which is not specifically recommended by the 
manufacturer he must ensure that the product will not be damaged or made unsafe and 
that there is no risk to persons or property.   
 

 

 
                  

Summary of Contents for TEC-11

Page 1: ...e TEC 11 removes condensate automatically from compressed air filters and i e small dental compressors The TEC 11 is designed for ALL compressed air filters regardless of their capacity or size The TE...

Page 2: ...fe working practices and observe all regulations and legal requirements for safety when operating this product When handling operating or carrying out maintenance on this product personnel must employ...

Page 3: ...3 EXPLODED VIEW IDENTIFY ALL COMPONENTS DIAGRAM Top nut Coil Flat gasket TEC 11 timer Connector gasket Connector Screw Shaft Spring Plunger Body...

Page 4: ...ed out 3 The drain is shipped fully assembled Disassemble the drain before installation by unscrewing the screw in the connector and the top nut above the coil see page 3 for an exploded view 4 Locate...

Page 5: ...the gasket and the coil 7 Mount the timer on to the coil as illustrated below 8 Remove the protection cap from the connector and connect your power cable to the connector as shown below 9 Place the c...

Page 6: ...lve function 14 Adjust the OFF button to suit your system i e 20 min 13 The drain is now at full system pressure and will periodically discharge any condensate it receives from your compressed air sys...

Page 7: ...out 1 Close the condensate supply i e close the ball valve in front of the filter 2 Press the TEST button to empty the unit of any residual condensate and to depressurise the TEC 11 valve 3 Switch off...

Page 8: ...ing a 13 mm wrench 10 Swith on the electrical supply 9 Reposition the coil timer and connector assembly on to the valve replace the top nut and tighten the top nut max torque 1Nm using a 14 mm wrench...

Page 9: ...9 SERVICE CHART Date Description Name...

Page 10: ...on DIN 43650B ISO 6952 Indicators Yellow LED s indicating on off Valve type 2 2 Way direct acting valve Connections 1 8 or 1 4 BSP or NPT Max Pressure 0 16 BAR 21 bar optional Operating Temperature 2...

Reviews: