HANGING THE APPLIANCE
OUTDOOR USE ONLY –
The appliance
must be used outdoors only and is to be
operated no closer than 500mm from the
sides and 1000mm from above to all
combustible surfaces, fabrics, flammable
materials & people
The appliance is designed to be hung
upright against a n o n - c o m b u s t i b l e
vertical surface. Do not operate from a
non-upright position. Doing so can be
dangerous and will damage the appliance.
During operation ensure that both air inlets
and the top exhaust are kept free from
obstructions and closure
Air inlet
– Left side
Air inlet
– Right side
Air Exhaust
– Top Side
APPLIANCE PERFORMANCE
Important –
This appliance is designed to
be used with a source water temperature of
20°C or below. If the temperature of the
outlet water exceeds 50°C the burners will
shut off; you will be required to turn the
water flow off and back on to reignite the
burners.
This appliance is designed to raise the
outlet water temperature by a maximum
(average) of 25°C above the source water
temperature and can be adjusted by the
gas regulator and water regulator
control knobs located at the front of the
device.
SAFETY FEATURES
The appliance is equipped with the
following safety features:
Over temperature sensor
– the appliance
will not allow the burner to remain in
operation
once
the
outlet
water
temperature reaches 50°C. To relight the
burner you will need to turn the water flow
off and back on.
Water flow sensor –
water must be
flowing through the system to allow the
burner to ignite. In the case that the water
supply is restricted or ceases, for example
if you close the water flow at the shower
nozzle, the burner will be extinguished and
will not relight until the water flow
recommences.