When unloading modules from vehicle, less than 
2  lots  package  could  be  lifted  each  time  with  a 
reasonable fixture. Before lifting, ensure that the 
trays and cartons undamaged, the hoisting ropes 
are durable. When the hoisting is near the ground, 
two  men  put  carton  gently  on  a  relative  flat 
position. Using a forklift to remove modules from 
the truck, unloaded modules should be placed on 
a level surface. The depth of forklift forks into the 
pallet  shall  not  be  less  than  3/4  of  the  pallet 
length.

When modules is temporarily stored in a project 
site,  modules  should  be  placed  in  a  dry  and 
ventilated  place.  Do  not  stack  modules  at  a 
project site. Cover modules with a tarpaulin, the 
tarpaulin should be fixed by a curtain or mesh belt 
to protect modules from moisture and rain.

Please store the modules in a dry and ventilated 
environment  and  place  the  modules  on  a 
relatively flat ground to avoid package damage or 
dumping due to ground deformation or collapse. 
Storage 

requirements: 

humidity 

<85%, 

temperature range -40 ℃ -50 ℃.

If the modules need long-distance transportation 
or long-term storage, do not remove the original 
packaging,  and  keep  the  wrapping  film  and 
packaging carton intact.

If the module would be transported for a too long 
distance or stored for a long period, it is forbidden 
to remove the original package. Modules 

packaged  with  original  package  could  be 
transported  by  land,  sea  or  air.  During 
transportation, fixing the package to the transport 
platform  to  ensure  it  would  not  be  tumbled. 
Taking land transportation as an example. When 
transported with truck, stacking up should be less 
than  two  layers,  it  is  forbidden  to  cut  the 
packaging  belts  of  packages.  There  shall  be  no 
gap between pallets or between pallets and truck 
supports. If there is a gap, it must be filled with 
fillers  (inflatable  bags,  etc.)  to  prevent  modules 
from tilting and shaking during transportation.

It  is  forbidden  to  remove  the  original  package 
when modules transported at a project site. One 
pallet  transported  each  time  is  required.  During 
transportation,  fixing  package  to  the  transport 
platform to ensure that the package would not be 
tumbled.  Do  not  use  tricycle  to  transport 
modules.  Do  not  handle  modules  with  rope 
during transportation, and it is forbidden to carry 
or drag modules through the wires or junction box 
of the modules.

Summary of Contents for HD120N

Page 1: ...INSTALLATION MANUAL Jolywood N type Mono crystalline Double Glass Module M6 Double glass module HD120N P HD144N P All rights reserved Jolywood Taizhou Solar Technology Co Ltd...

Page 2: ...tallation Installation Safety Mechanical installation and precautions Framed Bifacial Double Glass Modules installation with clamps Grounding Electrical installation Wiring Fuse Maintenance for PV Mod...

Page 3: ...er required relevant professional knowledge and the system must be installed and maintained by quali ed person with professional knowledge Please store this guide in a safe place for future reference...

Page 4: ...by quali ed person with professional knowledge Persons without authorization and relevant training should not touch modules and approach the installation area or module storage area Do not connect the...

Page 5: ...irectly on the module during transportation Improper transportation or installation also may damage module which is excluded from the warranty Do not stand climb walk or jump on unpacked pallets of mo...

Page 6: ...on a relatively at ground to avoid package damage or dumping due to ground deformation or collapse Storage requirements humidity 85 temperature range 40 50 If the modules need long distance transport...

Page 7: ...rly xed The ground needs to be at enough to ensure package could be placed horizontally and stably Supportive tool should be used when disassembling the carton to prevent the modules from falling down...

Page 8: ...during installation Do not open the electrical connection or pull out the connector while the circuit is under load Do not touch the modules during installation unless necessary Glass surfaces and bra...

Page 9: ...e 5 1 9 The application level of module produced by Jolywood is Class A modules with di erent color should be avoided from installed in the same array or roof Mounted with 4 clamps along long frame C...

Page 10: ...350 30mm maximum test load front 5400Pa back 2400Pa JW HD120N P Mounted with 4 clamps along short frame C shaped steel parallel to the short frame Edge Clamp width 40 50mm height 30mm A 250 30mm maxim...

Page 11: ...holes on the back of the module frame are installed on the support structure with Mounted with 4 clamps along long frame C shaped steel parallel to the long frame Edge Clamp width 40 50mm height 30mm...

Page 12: ...a and the recommended torque is 16 Newton m 5 2 3 4 The outer at washer needs to use M8 A2 70 a stainless steel SUS304 at washer with an outer diameter of 20 2 mm and a thickness of 1 1 1 2 mm the cor...

Page 13: ...ed in accordance with the appropriate National Electrical Code The grounding conductor or grounding wire could be made with copper copper alloy or other material which should also be in accordance wit...

Page 14: ...of modules connected wrong may lead to irreparable damage Before modules connected in parallel please check the voltage and polarity of each module array If the polarity of products is opposite or Vo...

Page 15: ...wn in Figure 2 Connecting modules in series in Parallel by inserting the positive terminal of one module into the negative terminal of the next module The number of modules connected in series or in p...

Page 16: ...free from damage and rust free ensure that the mountings properly tightened check all cables to make sure they are tight 6 2 3 It is forbidden to use WD 40 or various organic solvents to wipe all part...

Page 17: ...ules under special weather wind level greater four heavy rain or heavy snow c During cleaning the water pressure on the surface of module glass shall not exceed 4MPa and the module is not allowed to w...

Page 18: ...ash accumulation there is no obvious scratch on the surface of module No cracking occurs on the surface of module 6 3 3 Troubleshooting If module does not work after installation please notify the ins...

Reviews: