6.3     Cleaning

The  amount  of  electricity  produced  by  a  solar 
module  is  proportional  to  the  amount  of  light 
reach  on  surface  of  it.  A  dust  covered  module 
produces relatively lower power, so it is important 
to keep module clean.

6.3.1     Water quality requirements

6.3.2     Module inspection after 

             cleaning

6.3.2.1

PH: 5 ~7;
Chloride or salt content:0 - 3,000 mg/L;
Turbidity:0-30 NTU;
Conductivity:1500~3000 μs/cm;
Total dissolved solids:≤1000 mg/L;
Water hardness:0-40 mg/L;
Non-alkaline  water  must  be  used,  use 
demineralized  water  when  conditions  are 
available.

Note: when using robot clear modules, Jolywood 
recommends  using  soft  plastic  brush.  Module 
damage,  poor  appearance  and  power 
degradation caused by improper robot clear are 
not within the warranty scope of Jolywood;

a) 

The PV module should be cleaned under 

the  irradiance  of  less  than  200W/m2.  Avoiding 
cleaning  water  with  great  different  temperature 
from air to avoid cracking. Hard water needs to be 
softened. The water remains should be removed 
from glass surface after cleaning.

b) 

It is strictly forbidden to clean PV modules 

under  special  weather:    wind  level  greater  four, 
heavy rain or heavy snow.

c) 

During  cleaning,  the  water  pressure  on 

the surface of module glass shall not exceed 4MPa 
,  and  the  module  is  not  allowed  to  withstand 
additional external force.

d) 

During cleaning, it is strictly forbidden to 

step on the modules, splashing water to the back 
of the modules or cables. Ensure that connectors 
are  clean  and  dry  to  prevent  electric  shock  and 
fire  hazard.  Steam  clean  machines  are  strictly 
prohibited;  soft  parts,  Cloth  and  mild  detergent 
and  water  should  be  used.  Do  not  put  modules 
directly  into  the  water.  Serious  thermal  shocks 
also could damage modules.

e) 

The difficult-to-clean substances such as 

oil on the surface of modules, use a non-friction 
neutral  liquid  cleaner.  Do  not  use  any  organic 
solvent  containing  alkali  or  acid.  Do  not  use 
corrosive solvents or wipe the PV modules with a 
hard object.

f) 

If you are not sure whether the array need 

to  cleaned,  first  select  a  column  of  particularly 
dirty  array  to  begin  cleaning.  If  the  power 
generated  increased  less  than  5%,  cleaning  is 
usually  not  required.  The  above  verification 
should  be  carried  out  only  under  a  stable 
sunshine rate (sunny, strong sunshine, no cloud).

g) 

The back of the PV module usually does 

not need to be cleaned;  If you need to clean the 
back of the PV module , ensure that the cleaning 
liquid does not penetrate into the bottom layer of 
the material. 

h) 

Regularly  trim  the  vegetation  to  prevent 

shading  created  on  the  module  surface,  which 
would decrease power generation. 

Summary of Contents for HD120N

Page 1: ...INSTALLATION MANUAL Jolywood N type Mono crystalline Double Glass Module M6 Double glass module HD120N P HD144N P All rights reserved Jolywood Taizhou Solar Technology Co Ltd...

Page 2: ...tallation Installation Safety Mechanical installation and precautions Framed Bifacial Double Glass Modules installation with clamps Grounding Electrical installation Wiring Fuse Maintenance for PV Mod...

Page 3: ...er required relevant professional knowledge and the system must be installed and maintained by quali ed person with professional knowledge Please store this guide in a safe place for future reference...

Page 4: ...by quali ed person with professional knowledge Persons without authorization and relevant training should not touch modules and approach the installation area or module storage area Do not connect the...

Page 5: ...irectly on the module during transportation Improper transportation or installation also may damage module which is excluded from the warranty Do not stand climb walk or jump on unpacked pallets of mo...

Page 6: ...on a relatively at ground to avoid package damage or dumping due to ground deformation or collapse Storage requirements humidity 85 temperature range 40 50 If the modules need long distance transport...

Page 7: ...rly xed The ground needs to be at enough to ensure package could be placed horizontally and stably Supportive tool should be used when disassembling the carton to prevent the modules from falling down...

Page 8: ...during installation Do not open the electrical connection or pull out the connector while the circuit is under load Do not touch the modules during installation unless necessary Glass surfaces and bra...

Page 9: ...e 5 1 9 The application level of module produced by Jolywood is Class A modules with di erent color should be avoided from installed in the same array or roof Mounted with 4 clamps along long frame C...

Page 10: ...350 30mm maximum test load front 5400Pa back 2400Pa JW HD120N P Mounted with 4 clamps along short frame C shaped steel parallel to the short frame Edge Clamp width 40 50mm height 30mm A 250 30mm maxim...

Page 11: ...holes on the back of the module frame are installed on the support structure with Mounted with 4 clamps along long frame C shaped steel parallel to the long frame Edge Clamp width 40 50mm height 30mm...

Page 12: ...a and the recommended torque is 16 Newton m 5 2 3 4 The outer at washer needs to use M8 A2 70 a stainless steel SUS304 at washer with an outer diameter of 20 2 mm and a thickness of 1 1 1 2 mm the cor...

Page 13: ...ed in accordance with the appropriate National Electrical Code The grounding conductor or grounding wire could be made with copper copper alloy or other material which should also be in accordance wit...

Page 14: ...of modules connected wrong may lead to irreparable damage Before modules connected in parallel please check the voltage and polarity of each module array If the polarity of products is opposite or Vo...

Page 15: ...wn in Figure 2 Connecting modules in series in Parallel by inserting the positive terminal of one module into the negative terminal of the next module The number of modules connected in series or in p...

Page 16: ...free from damage and rust free ensure that the mountings properly tightened check all cables to make sure they are tight 6 2 3 It is forbidden to use WD 40 or various organic solvents to wipe all part...

Page 17: ...ules under special weather wind level greater four heavy rain or heavy snow c During cleaning the water pressure on the surface of module glass shall not exceed 4MPa and the module is not allowed to w...

Page 18: ...ash accumulation there is no obvious scratch on the surface of module No cracking occurs on the surface of module 6 3 3 Troubleshooting If module does not work after installation please notify the ins...

Reviews: