14
CHAP.04 USER MENU
04.1 FUNCTIONS
The display is divided into menus and sub-menus that can be scrolled using the radio control keys. In short, main menus and their
functions are:
MENU
Description
1 - SET CLOCK
Lets you set the current date and time, required for correct chronothermostat operations
2 - SET CHRONO
Lets you turn the chronothermostat and its programs on or off.
3 - SET LANGUAGE
Lets you set the menu language
4 - SET PROBE
Lets you set the type of probe to be used.
•
Set THERMOSTAT probe type to use a thermostat to control the appliance. If a retail thermostat
is used, the device must be used with clean contacts to the appliance.
WARNING
: using a
retail thermostat it is not possible to change the device on and off settings, but only the thermal
regulation settings. It must always be switched on and off via the Jolly-Mec Remote Control.
•
Set PROBE type to use the probe installed on the stove or a remote same type of probe in another
room. In the latter case, the probe installed on the stove must be disconnected from the electronic
card (to be done by the specialised Technical Service Center).
•
Set RADIO CONTROL probe type (factory settings) to use the remote control as a room probe.
5 - SET STAND-BY
STAND-BY mode lets you turn off the appliance when room request, according to the set configuration,
is met. In STAND-BY (display message) the appliance is awaiting room requests to restart a switch-on
cycle. The delay time delays shutdown from the moment when the requests are met. If PROBE type
was set in MENU 4, the appliance will only shutdown after running in ECONOMY mode for a period of
time equal to DELAY OFF time after requests are met while if THERMOSTAT type is set, the appliance
will run in ECONOMY mode for twice as long as the set DELAY OFF time.
6 - SET DISPLAY
Lets you set the user interface, and change the device buzzer settings.
7 - LOAD PELLET
Lets you start manual pellet load. It can be used after the completely empty tank is filled with fuel, to
fill load auger.
8 - STATE STOVE
Lets you view operating status in real-time.
9 - TECHNIC SETTINGS
This menu contains the appliance settingspages that only the specialised Technical Service Center
can access using a specific password.
10 - SET ADJUST-
Lets you change pellet loading and fume exhaust settings
11 - READ MEMORY
Lets you read some data stored in the control unit memory
13 - CHECK FLOW
This menu contains the Coaxial Control system settings (if available). Only a specialised Technical