For ducting to several rooms fit the T connection or Y connection (optional) and connect the two top outlets as
well as the ducting
WARNING
07.6
EXAMPLE OF HOT AIR CANALISATION (for forced air version only)
To duct the air into other rooms, assembly the “T” or “Y” connection (optional), in addiction to connect the grilles on the lining.
The air pipes must be routed to the rooms to be heated.
The return of air in the fireplace room must be guaranteed from every room in which the hot air arrives, through openings under the
doors or vents (see
F
ig
. 1-2
).
The air can be delivered, outside the hood and flue, by means of flexible aluminium pipes with connections and branches in sheet metal.
The pipes must be fixed to the connections by means of pipe clamps.
The pipes must be insulated to ensure fireplace efficiency. Therefore they must be wrapped with glass wool matting (min. thickness
3 cm) along their entire length (not inside the hood).
N.B. Avoid contact of the pipes with wood and flammable materials.
Using plastic pipes to deliver the air is very dangerous because the high temperatures could deform them and generate harmful gases.
Where the ducting pipes cannot be embedded, they can be concealed with a false ceiling or using fake beams or boxing (see
F
ig
. 1-2
).
Make sure to hermetically seal the space between the outlets and the wall with silicone, to prevent the air escaping and causing
blackening due to the heat (e.g. marks above radiators).
MAX. DUCTABLE LENGTH 6 METRES.