background image

www.johnsonsystems.com

8

COM
V+
ON
DIM
RST

CS-DMX-12

DC POWER SUPPLY COMMON  (V-) INPUT
DC POWER SUPPLY POSITIVE  (V+) INPUT

COM
V+

DMX OUT

CS-DMX-12

DMX OUT

DMX IN

COM
V+
ON
DIM
RST

Wiring Two or More Control Stations Together      
with “Mimic”

“Mimic” refers to pressing a button (“ON”, “DIM” or “OFF”) on a control station, and the other 

control station(s) are automatically triggered into the same “ON”, “DIM” or “OFF” state. The 

analog output(s) could be controlling the same device or completely different device. Wiring 

between the control stations requires 2 conductors for V+ and common, and 3 conductors          

(2 conductors for Part Number: CS-SA-ENT2B) for the switches (ON, DIM and RST), 1 conductor 

for each switch function. A DMX cable between the control stations is required, along with a DMX 

cable from one of the master control stations to the DMX receiving device.

Mounting the Control Station

The control station can be mounted on/in a gangable (usually masonry) type of back box 

with a minimum depth of 2" (50.8mm) and a preferred depth of 3.5" (88.9mm). A #2 Phillips 

head screwdriver is required to secure the control station, using the provided black #6-32 x 1" 

(25.4mm) mounting screws.
NOTE:  Ensure the back box is earth grounded to protect the control station from electrostatic 

discharge. 

NOTE:  Ensure the back box mounting-hole threads are not damaged. Damaged threads on the 

back box can damage the threads on the mounting screws and cause stripping. The back 

box threads can quickly be cleaned up by running a #6-32 tap through the mounting hole. 

Be sure not to over-tighten the mounting screws or this could result in stripping the back 

box mounting-hole threads.

Calibrate the DMX Output Range

All CS-DMX Series control stations are factory calibrated for 0-100% DMX control with a 10.6VDC 

to 18VDC power supply. If the control station does not have a full range of DMX control, please 

consult a factory representative.

Configure the Control Station Using a CS-IPRO 
Wireless Hand-Held Programmer

To configure the control station, a Johnson Systems Inc. Model Number: CS-IPRO wireless hand-

held programmer is required. The CS-IPRO is required primarily to configure the DMX channel 

patch for each of the sliders, however, it provides several other useful features.
Wireless communication between the CS-IPRO and CS-DMX Series control stations is via 

bidirectional infrared LED’s. The control station infrared LED window is located between the 

master (M) slider and slider 1. The maximum range for sending and receiving data between the 

control station and CS-IPRO is 12" (30cm).
NOTE:  Refer to the CS-IPRO user manual for detailed programming information.

Summary of Contents for CS-DMX Series

Page 1: ... Calgary Alberta Canada T2G 5M1 tel 403 287 8003 fax 403 287 9003 e mail info johnsonsystems com website www johnsonsystems com User Manual CS DMX Series Programmable Manual DMX Stations JOHNSON SYSTEMS INC www johnsonsystems com ...

Page 2: ... Secondary 3 6 9 or 12 Sliders 5 Control Station Security Feature 5 Power Supply Requirement 6 Control Station Wiring 6 DMX Input and Output Wiring 6 Wiring an Independent Control Station 7 Wiring a Single or Multiple Entrance Control Stations to a Master Control Station 7 Wiring Two or More Master Control Stations Together with Take Control 7 Wiring Two or More Control Stations Together with Mimi...

Page 3: ...tensity allow customization for demanding applications Durable powder coat finish is available in either black or white CS DMX Series Programmable Manual DMX Station Features Manual DMX at your fingertips Six models sizes available including two and three button entrance stations 512 DMX channels of control per station Multiple stations can be daisy chained on the same DMX line Digitally adjustabl...

Page 4: ...g Output DMX Output Range Calibration Jumper JP1 Security Enable Disable Jumper JP2 Factory Only Jumper s DMX Input Connector J1 DMX Output Connector J2 DMX Termination Jumper JP1 ON DIM and OFF Buttons With Integral LED s Master M Slider Infared LED Sensor Secondary 3 6 9 or 12 Sliders CS DMX Series Control Station Diagrams ...

Page 5: ...nnels patched to the sliders The OFF button corresponds with the RST reset connection on J1 and is optionally connected to other control stations for various applications NOTE The control station will still transmit DMX output levels at zero percent 00 in the OFF state Master M Slider The master slider controls the overall maximum DMX output level for the secondary sliders It has similar functiona...

Page 6: ...X in DMX IN and a 3 position breakaway connector used to transmit DMX out DMX OUT The DMX received on the DMX in if applicable connector is merged with the DMX generated by the control station and retransmitted through the DMX out connector Merged DMX data is highest takes precedence HTP for equivalent DMX control channels There is only a 1 packet 28msec delay in the retransmitted DMX from the ori...

Page 7: ...ly installed at an entrance location and used to trigger a master control station into the ON DIM or OFF state The entrance station s and master station mimic each other when a button is pressed Wiring between a single or multiple entrance stations and master station requires 2 conductors for V and common and 3 conductors for the switches ON DIM and RST 1 conductor for each switch function A singl...

Page 8: ...the control station from electrostatic discharge NOTE Ensure the back box mounting hole threads are not damaged Damaged threads on the back box can damage the threads on the mounting screws and cause stripping The back box threads can quickly be cleaned up by running a 6 32 tap through the mounting hole Be sure not to over tighten the mounting screws or this could result in stripping the back box ...

Page 9: ... is counted press the ON button to save the time fade and exit To set the time fade to zero no fading press and hold the ON button for approximately 10 seconds until the ON LED extinguishes Release the ON button and immediately press the ON button again before the ON LED flashes on Set the Button LED Intensity The button LED intensity can be adjusted to a preferred intensity level for various envi...

Page 10: ...ED flashes off for 0 1 seconds every 2 seconds to indicate remote lockout mode is activated Procedure To activate the remote lockout mode press and hold the DIM button for approximately 10 seconds until the DIM LED flashes off for 0 1 seconds To deactivate the remote lockout mode press and hold the DIM button for approximately 10 seconds until the DIM LED flashes off for 0 1 seconds Short Circuit ...

Page 11: ...www johnsonsystems com 11 CS DMX Series Typical Wiring Applications ...

Page 12: ...ang 2 button on off entrance station with adjustable on voltage for stand alone applications 5 x 18 AWG 1 gang 1 80 W x 2 75 H x 2 00 D 4 6cm x 7 0cm x 5 1cm CS SA ENT3B 1 gang 3 button entrance station w on preset and off 6 x 18 AWG 1 gang 1 80 W x 2 75 H x 2 00 D 4 6cm x 7 0cm x 5 1cm CS IPRO Hand held Infrared Station Programmer 2 75 W x 4 95 H x 1 00 D 70cm x 125cm x 25cm Wireless N A N A DMX ...

Reviews: