Introduction

Multi-Station, multi-room manual DMX controls for a full DMX 

universe of control!
Value, power and complete flexibility in a “green”, user friendly, 

cost-effective package! The DMX Series of controls are the most 

capable manual “stand-alone” DMX controls available. These field 

programmable controls support 512 channels of DMX data with 

digitally adjustable fade times. Multiple stations can be daisy-chained 

together on the same control wire permitting multiple stations per 

room. Each station can be individually programmed with our wireless 

infrared hand-held programmer (Model Number: CS-IPRO) permitting 

any slider/channel assignments imaginable.
Available from single to 12 channels with master, preset and take 

control functions. Two and three button entrance station can be 

remotely “locked out” for application where access needs to be 

limited. This series of controls will operate on DC supply voltages 

up to 18 volts. Adjustable time fade and LED intensity allow 

customization for demanding applications. Durable powder-coat finish 

is available in either black or white.

CS-DMX Series

Programmable Manual

DMX Station

Features

•  Manual DMX at your fingertips.

•  Six models/sizes available including two and three button entrance 

stations.

•  512 DMX channels of control per station.

•  Multiple stations can be daisy-chained on the same DMX line.

•  Digitally adjustable fade-times and LED brightness.

•  Station programming via low cost, wireless infrared hand-held remote.

•  Local or remote/entrance station lockout options.

•  Short-circuit and over-current protection.

•  Ruggedly built for reliability and longevity.

•  Tough, durable powder coat paint on 0.080” aluminum laser cut 

faceplate for a scratch resistant non-glare finish.

•  Color matched and sized for use with Johnson Systems AP Series 

adapter plates where necessary to adapt to existing (larger) electrical 

back boxes.

•  Metal shaft sliders and machine screw mounting help prevent broken or 

missing parts.

•  Heavy-duty "high tactile" pushbutton switches are rated for 5 million 

operations.

•  Optional 6 Port Cascading Installation Merger permits low cost DMX 

universe combining.

CS-IPRO

Wireless Hand-held

Programmer

Summary of Contents for CS-DMX Series

Page 1: ... Calgary Alberta Canada T2G 5M1 tel 403 287 8003 fax 403 287 9003 e mail info johnsonsystems com website www johnsonsystems com User Manual CS DMX Series Programmable Manual DMX Stations JOHNSON SYSTEMS INC www johnsonsystems com ...

Page 2: ... Secondary 3 6 9 or 12 Sliders 5 Control Station Security Feature 5 Power Supply Requirement 6 Control Station Wiring 6 DMX Input and Output Wiring 6 Wiring an Independent Control Station 7 Wiring a Single or Multiple Entrance Control Stations to a Master Control Station 7 Wiring Two or More Master Control Stations Together with Take Control 7 Wiring Two or More Control Stations Together with Mimi...

Page 3: ...tensity allow customization for demanding applications Durable powder coat finish is available in either black or white CS DMX Series Programmable Manual DMX Station Features Manual DMX at your fingertips Six models sizes available including two and three button entrance stations 512 DMX channels of control per station Multiple stations can be daisy chained on the same DMX line Digitally adjustabl...

Page 4: ...g Output DMX Output Range Calibration Jumper JP1 Security Enable Disable Jumper JP2 Factory Only Jumper s DMX Input Connector J1 DMX Output Connector J2 DMX Termination Jumper JP1 ON DIM and OFF Buttons With Integral LED s Master M Slider Infared LED Sensor Secondary 3 6 9 or 12 Sliders CS DMX Series Control Station Diagrams ...

Page 5: ...nnels patched to the sliders The OFF button corresponds with the RST reset connection on J1 and is optionally connected to other control stations for various applications NOTE The control station will still transmit DMX output levels at zero percent 00 in the OFF state Master M Slider The master slider controls the overall maximum DMX output level for the secondary sliders It has similar functiona...

Page 6: ...X in DMX IN and a 3 position breakaway connector used to transmit DMX out DMX OUT The DMX received on the DMX in if applicable connector is merged with the DMX generated by the control station and retransmitted through the DMX out connector Merged DMX data is highest takes precedence HTP for equivalent DMX control channels There is only a 1 packet 28msec delay in the retransmitted DMX from the ori...

Page 7: ...ly installed at an entrance location and used to trigger a master control station into the ON DIM or OFF state The entrance station s and master station mimic each other when a button is pressed Wiring between a single or multiple entrance stations and master station requires 2 conductors for V and common and 3 conductors for the switches ON DIM and RST 1 conductor for each switch function A singl...

Page 8: ...the control station from electrostatic discharge NOTE Ensure the back box mounting hole threads are not damaged Damaged threads on the back box can damage the threads on the mounting screws and cause stripping The back box threads can quickly be cleaned up by running a 6 32 tap through the mounting hole Be sure not to over tighten the mounting screws or this could result in stripping the back box ...

Page 9: ... is counted press the ON button to save the time fade and exit To set the time fade to zero no fading press and hold the ON button for approximately 10 seconds until the ON LED extinguishes Release the ON button and immediately press the ON button again before the ON LED flashes on Set the Button LED Intensity The button LED intensity can be adjusted to a preferred intensity level for various envi...

Page 10: ...ED flashes off for 0 1 seconds every 2 seconds to indicate remote lockout mode is activated Procedure To activate the remote lockout mode press and hold the DIM button for approximately 10 seconds until the DIM LED flashes off for 0 1 seconds To deactivate the remote lockout mode press and hold the DIM button for approximately 10 seconds until the DIM LED flashes off for 0 1 seconds Short Circuit ...

Page 11: ...www johnsonsystems com 11 CS DMX Series Typical Wiring Applications ...

Page 12: ...ang 2 button on off entrance station with adjustable on voltage for stand alone applications 5 x 18 AWG 1 gang 1 80 W x 2 75 H x 2 00 D 4 6cm x 7 0cm x 5 1cm CS SA ENT3B 1 gang 3 button entrance station w on preset and off 6 x 18 AWG 1 gang 1 80 W x 2 75 H x 2 00 D 4 6cm x 7 0cm x 5 1cm CS IPRO Hand held Infrared Station Programmer 2 75 W x 4 95 H x 1 00 D 70cm x 125cm x 25cm Wireless N A N A DMX ...

Reviews: