Pressure and capacity data
Pressure
Flow
Amp. draw
Bar kPa Psi L/min USGPM
12V 24V
0
0
0 34.4 9.1
2.5 1.2
0.1 10 1.5 30.8 8.1
3.3 1.6
0.2 20 2.9 27.1 7.2
4.2 2.1
0.3 30 4.4 23.5 6.2
5.0 2.5
0.4 40 5.8 20.0 5.3
5.6 2.8
0.5 50 7.2 16.7 4.4
6.1 3.1
Fuse required
12 A 6 A
Installation and maintenance
Installation
• Mount the pump in a dry location.
• If the pump is mounted vertically, the
motor must be above the pump house.
• Mark screw positions and drill pilot
holes.
• Mount the pump using stainless steel
screws and the enclosed washers. Make
sure that the plastic spacers are in their
correct position. NOTE: Take care not
to fasten the vibration-damping rubber
feet too much.
• Mount the outlet anti-drainback valves
and screw the connections - Viking
Power Vacuum.
NOTE: The anti-drainback valves are
mounted with the pointed end towards
the flow direction. See the drawing.
• Reinforced flexible tubing is recom-
mended.
• Use stainless steel hose clamps to secure
tubing to connections and other hose
barbs in the system.
electrical installation
The pump must be installed according to
ISO 10133 (Small craft – Electrical system
– Extra low voltage DC installation).
NOTE: The fuse must be ignition protected.
The motor is equipped with built-in ther-
mal protection to prevent overheating. The
protection is automatically restored when
the motor is cooled. See the wiring diagram
for correct installation. Negative wire must
be black.
Choose wire size in accordance with total
wire length (see table). The wire connec-
tions must be sealed with a marine sealant.
NOTE: Before installation with electrical
control systems, check that equipment to
be used is of sufficient rated capacity to ac-
cept amperage draw of motor. Low voltage
can cause the motor to overheat.
Maintenance
The pump valves inside the pump house
should be regularly cleared from debris to
prevent reduced performance and poor self
priming capability. This is done by unscre-
wing the house clamp and opening the
house. The outlet
anti-drainback valves are located above
the connections. (Viking Power Vacuum.)
NOTE: Make sure the pump is disconnec-
ted from the power supply.
Wiring diagram
Other electrical devices such as circuit breaker
and relays must be installed between the pulp
and the positive (+) lead on the battery (on the
red wire).
Pump
Terminal
fuse
Switch
Max 0.2 m
Red
Black
Green/yellow
+
–
Wiring dimensions
(Based on 10% voltage drop)
Wire size
Max wire length* in m
12V
24V
1.5 mm²
#16 AWG
18
71
2.5 mm²
#14 AWG
30 118
* The wire length is the total distance from the
battery to the pump and back to the battery. It is
recommended to use a relay with a light wire from
the main cable to shorten the main leaders.
8