CLB/EN (1901) 6.6
Technical data
59
CombiLineBloc
10.4
Noise data
10.4.1
Pump noise as a function of pump power
Figure 25:
Noise level as function of pump power [kW] at 1450 min
-1
A = sound power level, B = sound pressure level.
Figure 26:
Noise level as function of pump power [kW] at 2900 min
-1
A = sound power level, B = sound pressure level.
54
56
58
60
62
64
66
68
70
72
74
76
78
80
82
84
86
88
90
92
94
96
98
0,1
1
10
100
200
P [kW]
[dB(A)]
A
4103_A
B
60
65
70
75
80
85
90
95
100
0,1
1
10
100
300
P [kW]
[dB(A)]
4104_A
A
B